{"title":"In Stock Items","description":"We are an Authorized Distributor of Pepperl \u0026amp; Fuchs Process Automation and Factory Automation products.  Featuring VIATOR Hart Modems, K-System and H-System Explosion proof and intrinsically safe barriers.  All in stock items ship within 1 day or in 3-5 days as labeled on their respective product pages.","products":[{"product_id":"epv-5500-aa-01-enclosure-protection-vent-30-scfm","title":"EPV-5500-AA-01, Enclosure Protection Vent, 30 SCFM","description":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003ePurge \u0026amp; Pressurization\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eManufacturer By:\u003c\/strong\u003e Pepperl+Fuchs Process Automation\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSeries:\u003c\/strong\u003e EPV Series\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cp\u003eDrains\/Vents, 5500 Series\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"big bold\"\u003eModel Number: EPV-5500-AA-01\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Enclosure Protection Vent, 30 SCFM\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003ch4 class=\"big bold\"\u003e5500 Series Information\u003c\/h4\u003e\nThe EPV‑5500 vent works with the 5500 control unit and manifold valve to form a certified purge and pressurization system for enclosures. It cannot be used alone. Vents are a required component for all pressurized enclosure systems. The EPV‑5500 functions as a pressure relief device, allowing the purge gas to exit the enclosure and includes a spark arrestor. The vent also provides a seal when enclosure is pressurized and operating. The 5500 series purge and pressurization system has NEC, CEC, ATEX and IECEx third part certifications for Class I, II\/Div. 2 and Zone 2\/22.\u003c\/div\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"EPV-5500-AA-01","offer_id":41089160184005,"sku":"515662","price":493.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/70526654.jpg?v=1601620914"},{"product_id":"hic2031","title":"HiC2031 SMART Current Driver","description":"\u003cdiv class=\"description\"\u003e\n\u003ch1 class=\"p-subtitle description-header\"\u003eSMART Current Driver HiC2031\u003cbr\u003e\n\u003c\/h1\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (bus powered)\u003c\/li\u003e\n\u003cli\u003eCurrent output up to 650 Ω load\u003c\/li\u003e\n\u003cli\u003eLow power dissipation\u003c\/li\u003e\n\u003cli\u003eSIL 2 (SC 3) acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eIt repeats the input signal from a control system to drive HART I\/P converters, valve actuators, and displays located in a hazardous area.\u003c\/p\u003e\n\u003cp\u003eDigital signals are superimposed on the analog values at the field side or control side and are transferred bi-directionally.\u003c\/p\u003e\n\u003cp\u003eAn open field circuit presents a high impedance to the control side to allow alarm conditions to be monitored by the control system.\u003c\/p\u003e\n\u003cp\u003eThis device mounts on a HiC termination board.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"information\"\u003e\n\u003cp class=\"resource-item\"\u003e\u003cspan class=\"info-item-image\"\u003e \u003cimg src=\"https:\/\/assets.alliedelec.com\/image\/upload\/v1543945169\/SiteImages\/AlliedElec\/pdf.svg\" alt=\"Datasheet\" title=\"Datasheet\"\u003e \u003c\/span\u003e \u003ca title=\"Download Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/190a0db7bb1c7f97803163df860ca337.pdf?v=1602792855\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"HiC2031","offer_id":36736386072729,"sku":"321426","price":520.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/Screenshot2021-12-28113106.png?v=1640709213"},{"product_id":"3004-wpsa-ci-yz-vml","title":"3004-WPSA-CI-YZ-VML, Encl Purge Sys, With Pressure Switch, Class I, Vertical LH Mnt","description":"\u003cdiv class=\"col-xs-12\"\u003e\n\u003ch3\u003ePurge and Pressurization Systems, 3004 Series\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"small bold\"\u003eIModelNumber: \u003c\/span\u003e\u003cspan class=\"big bold\"\u003e3004-WPSA-CI-YZ-VML\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Encl Purge Sys, With Pressure Switch, Class I, Vertical LH Mnt\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cdiv class=\"big bold\"\u003e3004 Series Information\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eNFPA 496, ISA 12.4, and ATEX Standards\u003c\/li\u003e\n\u003cli\u003eOptional Alarm Output Indicates Air Lock Failure\u003c\/li\u003e\n\u003cli\u003eOptional Differential Pressure Switch\u003c\/li\u003e\n\u003c\/ul\u003e\nModel 3004 is a Rapid Exchange® purging system that operates on a supply of compressed instrument air or inert gas. It regulates and monitors pressure within sealed protected enclosure(s), in order to remove and prevent flammable gas or vapor accumulations.\u003c\/div\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"3004-WPSA-CI-YZ-VML","offer_id":41007311880389,"sku":"513871","price":2167.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/70526328.jpg?v=1603927139"},{"product_id":"3004-wpsa-ci-yz-vml-24vdc","title":"3004-WPSA-CI-YZ-VML-24VDC, Encl Purge Sys, With Pressure Switch, Class I, Vertical LH Mnt","description":"\u003ch3\u003e\u003cspan data-mce-fragment=\"1\"\u003ePurge \u0026amp; Pressurization, Purge 3000 Series, 3004-WPSA-CI-YZ-VML-24VDC\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cp\u003e\u003cspan class=\"small bold\"\u003eItem Model\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"big bold\"\u003e3004-WPSA-CI-YZ-VML-24VDC\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Encl Purge Sys, With Pressure Switch, Class I, Vertical LH Mnt\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cdiv class=\"big bold\"\u003e3004 Series Information\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eNFPA 496, ISA 12.4, and ATEX Standards\u003c\/li\u003e\n\u003cli\u003eOptional Alarm Output Indicates Air Lock Failure\u003c\/li\u003e\n\u003cli\u003eOptional Differential Pressure Switch\u003c\/li\u003e\n\u003c\/ul\u003e\nModel 3004 is a Rapid Exchange® purging system that operates on a supply of compressed instrument air or inert gas. It regulates and monitors pressure within sealed protected enclosure(s), in order to remove and prevent flammable gas or vapor accumulations.\u003c\/div\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"3004-WPSA-CI-YZ-VML-24VDC","offer_id":41007311978693,"sku":"514014","price":2127.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/70526330.jpg?v=1603927141"},{"product_id":"3004-wpsa-ci-yz-vmr-vx-24vdc-encl-purge-sys-with-pressure-switch-class-i-vertical-rh-mnt-vortex-24-vdc","title":"3004-WPSA-CI-YZ-VMR-VX-24VDC, Encl Purge Sys, With Pressure Switch, Class I, Vertical RH Mnt, Vortex, 24 VDC","description":"\u003cdiv data-mce-fragment=\"1\" class=\"col-xs-12\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" class=\"small bold\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePurge and Pressurization Systems, 3004 Series\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\" class=\"small bold\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eModel Number: 3004-WPSA-CI-YZ-VMR-VX-24VDC\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e- Encl Purge Sys, With Pressure Switch, Class I, Vertical RH Mnt, Vortex, 24 VDC\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\" class=\"col-xs-12\"\u003e\n\u003cdiv data-mce-fragment=\"1\" class=\"big bold\"\u003e3004 Series Information\u003c\/div\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNFPA 496, ISA 12.4, and ATEX Standards\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOptional Alarm Output Indicates Air Lock Failure\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOptional Differential Pressure Switch\u003c\/li\u003e\n\u003c\/ul\u003e\nModel 3004 is a Rapid Exchange® purging system that operates on a supply of compressed instrument air or inert gas. It regulates and monitors pressure within sealed protected enclosure(s), in order to remove and prevent flammable gas or vapor accumulations.\u003c\/div\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"3004-WPSA-CI-YZ-VMR-VX-24VDC","offer_id":41005583696069,"sku":"515589","price":2358.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/70526354.jpg?v=1603927148"},{"product_id":"3004-wps-ci-yz-vml","title":"3004-WPS-CI-YZ-VML,  Encl Purge Sys, With Pressure Switch, Class I, Vertical LH Mnt","description":"\u003ch3 id=\"hdr2\" class=\"h2pgheaders\" data-mce-fragment=\"1\"\u003e\u003cspan id=\"hdr2text\" data-mce-fragment=\"1\"\u003ePepperl Fuchs Purge and Pressurization Systems, 3004 Series\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cp\u003e\u003cspan class=\"small bold\"\u003eItem Model\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"big bold\"\u003e3004-WPS-CI-YZ-VML\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e- Encl Purge Sys, With Pressure Switch, Class I, Vertical LH Mnt\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\"\u003e\n\u003cdiv class=\"big bold\"\u003e3004 Series Information\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eNFPA 496, ISA 12.4, and ATEX Standards\u003c\/li\u003e\n\u003cli\u003eOptional Alarm Output Indicates Air Lock Failure\u003c\/li\u003e\n\u003cli\u003eOptional Differential Pressure Switch\u003c\/li\u003e\n\u003c\/ul\u003e\nModel 3004 is a Rapid Exchange® purging system that operates on a supply of compressed instrument air or inert gas. It regulates and monitors pressure within sealed protected enclosure(s), in order to remove and prevent flammable gas or vapor accumulations.\u003c\/div\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"3004-WPS-CI-YZ-VML","offer_id":41002898751685,"sku":"513711","price":1974.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/70526334.jpg?v=1603927153"},{"product_id":"5500-man-cd01-24vdc","title":"5500-MAN-CD01-24VDC, 5500 Manifold","description":"\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eManifold\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan class=\"small bold\" data-mce-fragment=\"1\"\u003eItem#\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"big bold\" data-mce-fragment=\"1\"\u003e5500-MAN-CD01-24VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e5500 Manifold\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for Class I,II\/Div. 1 \u0026amp; 2 for hazardous locations\u003c\/li\u003e\n\u003cli\u003eCertifications for FM and CSA\u003c\/li\u003e\n\u003cli\u003eManifold combines the solenoid valve for purging and needle valve for pressurization in one housing\u003c\/li\u003e\n\u003cli\u003eSuitable for steel or plastic tubing\u003c\/li\u003e\n\u003cli\u003eMounting hardware, pneumatic fittings and tubing included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 5500-MAN-CD01- * combines a solenoid valve for purging and a needle valve for pressurization in one manifold design. When the valve is energized, the solenoid valve opens and allows for a high flow of protective gas into the enclosure. When the valve is de-energized, the flow through the internal needle valve is adjustable by a flathead screw driver through the needle stem located on the manifold. The solenoid valve is used for purging, leakage compensation, and temperature control by signals from user defined points on the 5500 control unit. Mounting hardware includes 3\/8\" tube compression fittings mounted on the manifold for input and output flow, 3\/8\" tube compression bulkhead fitting for getting flow into the enclosure and certified sealing washers with bolts to mount the manifold to the enclosure. Also included is 1 meter of 3\/8\" poly tubing with 3\/8\" poly tube stiffener inserts which allows the connection of plastic tubing to compression fittings without collapsing the tubing. The 5500 valve system works with the 5500 control unit and EPV-5500 vents. The 5500 Series system has FM and CSA certification for Class\/Division installation, see model number key for proper manifold selection. For ATEX and IECEx applications look the model number key proper manifold selection.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"5500-MAN-CD01-24VDC","offer_id":41007312830661,"sku":"515697","price":690.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/40E664A0-2DA7-4DBA-AC58-53AFE52165B7_069de83b-0126-452b-9071-42189d3fee13.png?v=1645146035"},{"product_id":"5500-man-cdul-120vac","title":"5500 Series manifold, UL certified, 5500-MAN-CDUL-120VAC","description":"\u003ch3\u003e\u003cstrong\u003e5500-MAN-CDUL-120VAC, 5500 Series manifold, UL certified, 120 VAC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"product-detail-header__usp-list\"\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eSuitable for Class I, II\/Div. 2 for hazardous locations\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eCertified for UL\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eManifold combines the solenoid valve for purging and needle valve for pressurization in one housing\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eSuitable for steel or plastic tubing\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eMounting hardware, pneumatic fittings and tubing included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 5500-MAN-CDUL-* combines a solenoid valve for purging and a needle valve for pressurization in one manifold design. When the valve is energized, the solenoid valve opens and allows for a high flow rate of protective gas into the enclosure. When the valve is deenergized, the flow through the internal needle valve is adjustable by using the included Hex key. The solenoid valve is used for purging, leakage compensation, and temperature control by signals from user defined points on the 5500 control unit.\u003c\/p\u003e\n\u003cp\u003eMounting hardware includes 3\/8\" tube compression fittings mounted on the manifold for input and output flow, 3\/8\" tube compression bulkhead fitting for getting flow into the enclosure and certified sealing washers with bolts to mount the manifold to the enclosure. Also included is 1 meter of 3\/8\" poly tubing with 3\/8\" poly tube stiffener inserts which allows the connection of plastic tubing to compression fittings without collapsing the tubing.\u003c\/p\u003e\n\u003cp\u003eFor NEC, ATEX and IECEx applications see the model number key for proper manifold selection.\u003c\/p\u003e\n\u003cp\u003eThe 5500 valve system works with the 5500 control unit and EPV-5500 vents. The 5500 system has UL certification for Class\/Division installation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"5500-MAN-CDUL-120VAC","offer_id":41005648609477,"sku":null,"price":680.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/5BFFF1D1-E3BB-4048-9EE8-4B5CB0BD230A.png?v=1770838525"},{"product_id":"5500-man-cdul-24vdc","title":"5500-MAN-CDUL-24VDC, 5500 series manifold","description":"\u003ch3 class=\"alternative\" data-mce-fragment=\"1\"\u003e5500 series manifold 5500-MAN-CDUL-24VDC\u003c\/h3\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003eSuitable for Class I, II\/Div. 2 for hazardous locations\u003c\/li\u003e\n\u003cli\u003eCertified for UL CSA\u003c\/li\u003e\n\u003cli\u003eManifold combines the solenoid valve for purging and needle valve for pressurization in one housing\u003c\/li\u003e\n\u003cli\u003eSuitable for steel or plastic tubing\u003c\/li\u003e\n\u003cli\u003eMounting hardware, pneumatic fittings and tubing included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e5500 series manifold, UL and CSA certified, 24 V DC\u003c\/p\u003e\n\u003cp\u003eThe 5500-MAN-CDUL-* combines a solenoid valve for purging and a needle valve for pressurization in one manifold design. When the valve is energized, the solenoid valve opens and allows for a high flow rate of protective gas into the enclosure. When the valve is deenergized, the flow through the internal needle valve is adjustable by using the included Hex key. The solenoid valve is used for purging, leakage compensation, and temperature control by signals from user defined points on the 5500 control unit. Mounting hardware includes 3\/8\" tube compression fittings mounted on the manifold for input and output flow, 3\/8\" tube compression bulkhead fitting for getting flow into the enclosure and certified sealing washers with bolts to mount the manifold to the enclosure. Also included is 1 meter of 3\/8\" poly tubing with 3\/8\" poly tube stiffener inserts which allows the connection of plastic tubing to compression fittings without collapsing the tubing. For NEC, ATEX and IECEx applications see the model number key for proper manifold selection. The 5500 valve system works with the 5500 control unit and EPV-5500 vents. The 5500 system has UL certification for Class\/Division installation.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"5500-MAN-CDUL-24VDC","offer_id":41007312896197,"sku":"515700","price":875.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/F4B1F8AC-DD01-4474-93E9-329B630ABBA2.png?v=1645147880"},{"product_id":"6000-dv-s2-un-wh-ac","title":"Purge \u0026 Pressurization System, 6000 Series, 6000-DV-S2-UN-WH-AC","description":"\u003ch4\u003e\u003cstrong\u003e6000-DV-S2-UN-WH-AC, Purge \u0026amp; Pressurization System, 6000 Series\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCertified for Class I, Class II, Division I; Zone 1 \/ Zone 21 to nonhazardous\u003c\/li\u003e\n\u003cli\u003eIntrinsically safe electrical\/pneumatic manifold assembly\u003c\/li\u003e\n\u003cli\u003eIntrinsically safe user interface for programming and monitoring the system\u003c\/li\u003e\n\u003cli\u003eEnclosure volume up to 450 ft3 (12.1 m3)\u003c\/li\u003e\n\u003cli\u003eControl Unit monitors system operation and controls enclosure power\u003c\/li\u003e\n\u003cli\u003eUniversal mounting (brackets included)\u003c\/li\u003e\n\u003cli\u003e316L stainless steel Type 4X enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe EPV‑6000 vent exhausts excess pressure from the enclosure and measures flow and pressure during operation. The 6000 series vent has a pressure transducer and thermal flow sensor that is connected to the 6000 EPCU. It is intrinsically safe through the galvanic isolation barrier within the 6000 EPCU.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe purpose of the Pepperl+Fuchs 6000 series Type X \u0026amp; Ex px, Class I\/II, Division 1 \/ Zone 1\/21 enclosure protection system is to allow the use of general purpose or nonrated electrical or electronic devices located in general purpose enclosures instead of explosionproof\/flameproof, Type 7 or 9 \/ Ex d enclosures or other means of protection for the rated area. Other purposes include heat, moisture, and dust contamination prevention. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 6000 series Type X \u0026amp; Ex px purge and pressurization system protects general purpose equipment mounted in a standard enclosure. This allows the enclosure to be located and the equipment operated in a hazardous area. The hazardous area classification can be Class I, Class II, Division 1 \/ Zone 1, Zone 21. The 6000 series operates by controlling and monitoring compressed instrument air or inert gas through the protected enclosure(s) so as to remove and prevent the accumulation of flammable gas, vapors, or dust. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 6000 series system features these main parts: \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eElectronic processor (EPCU) housed in an explosionproof enclosure \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eI.S. electrical\/pneumatic manifold assembly \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eI.S. user interface for programming and monitoring the system \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e316L stainless steel (UNS S31603) type 4X IP66 enclosure for EPCU and connections (not included with component kit)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntrinsically safe pressure relief vent with flow and pressure monitoring at the exhaust. \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe user interface allows programming of up to 4 switch inputs, temperature modules, enclosure power contacts, 2 auxiliary outputs, and various operational functions. Through the user interface menus, configuration of the standard information for setup and operation of a system (purge time, flow rates, pressures, enclosure size, etc.) are easily programmed. Additional features allow inputs for system bypass, enclosure power on\/off, temperature overload and activation of rapid exchange flow for cooling or auxiliary relay for separate cooling source, delay power shutdown, and more. The two auxiliary contact outputs can be configured to activate on most of the input switches or any of the configured alarm states for pressure, flows, and temperature. The power for the solenoid valve on the manifold unit, inputs, the user interface controller (UIC), and EPV-6000 vent are provided by the EPCU through the internal galvanically isolated intrinsic safety barrier. No additional I.S. barrier is required. The adjustable mounting bracket and the universally mountable vent make the 6000 system easy to install horizontally or vertically onto the enclosure. A component kit is available for custom installations that fit specific customer needs.The 6000 control unit can monitor multiple enclosures and control and accept inputs from two (2) EPV6000 vents. The 6000 series provides a complete system for purging and pressurizing enclosures for hazardous location operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"6000-DV-S2-UN-WH-AC","offer_id":41005634650309,"sku":null,"price":5275.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/97238B47-0A0D-4904-911A-A4E7D21E0B62.png?v=1770842811"},{"product_id":"6500-cblg-01-lbc","title":"6500-CBLG-01-LBC, Cable Gland Kit for 6500 Control Systems","description":"\u003cp\u003e6500 cable gland kit\u003c\/p\u003e\n\u003cp\u003e6500-CBLG-01-*\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete approved cable glands, plugs, and nuts for installation to the 6500 control unit\u003c\/li\u003e\n\u003cli\u003eSelection of material - stainless steel, nickel plated brass, or plastic\u003c\/li\u003e\n\u003cli\u003e ATEX\/IECEx approved \/ II 2G 1D\u003c\/li\u003e\n\u003cli\u003eIP68\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 6500 control unit does not come with cable glands so that customers can use their own approved glands. The 6500-CBLG offers a complete set of approved cable glands for the 6500 control unit I.S. and Power sides. Selection of material allows customers to select the best cable gland for their applications.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"6500-CBLG-01-LBC","offer_id":41005633831109,"sku":"515916","price":125.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/9B9AE334-0227-4873-BC70-64C18C1E95AD.png?v=1641235259"},{"product_id":"6500-cblg-01-cpc","title":"6500-CBLG-01-CPC, Cable Gland Kit for 6500 Control Systems","description":"\u003cp data-mce-fragment=\"1\"\u003e6500 cable gland kit\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e6500-CBLG-01-*\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eComplete approved cable glands, plugs, and nuts for installation to the 6500 control unit\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSelection of material - stainless steel, nickel plated brass, or plastic\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e ATEX\/IECEx approved \/ II 2G 1D\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIP68\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 6500 control unit does not come with cable glands so that customers can use their own approved glands. The 6500-CBLG offers a complete set of approved cable glands for the 6500 control unit I.S. and Power sides. Selection of material allows customers to select the best cable gland for their applications.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"6500-CBLG-01-CPC","offer_id":41005633765573,"sku":"515959","price":308.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/9B9AE334-0227-4873-BC70-64C18C1E95AD_f1b8ba97-f4e9-422e-9141-c2e073ee28c3.png?v=1641235887"},{"product_id":"6500-cblg-01-cbc","title":"6500-CBLG-01-CBC, Cable Gland Kit for 6500 Control Systems","description":"\u003cp data-mce-fragment=\"1\"\u003e6500 cable gland kit\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e6500-CBLG-01-*\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eComplete approved cable glands, plugs, and nuts for installation to the 6500 control unit\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSelection of material - stainless steel, nickel plated brass, or plastic\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e ATEX\/IECEx approved \/ II 2G 1D\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIP68\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 6500 control unit does not come with cable glands so that customers can use their own approved glands. The 6500-CBLG offers a complete set of approved cable glands for the 6500 control unit I.S. and Power sides. Selection of material allows customers to select the best cable gland for their applications.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"6500-CBLG-01-CBC","offer_id":41005633732805,"sku":"515958","price":323.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/9B9AE334-0227-4873-BC70-64C18C1E95AD_1e1d9704-5b1e-4f76-9e0f-9a36f90b421d.png?v=1641237699"},{"product_id":"6500-cblg-01-lsc","title":"6500-CBLG-01-LSC, Cable Gland Kit for 6500 Control Systems","description":"\u003cp data-mce-fragment=\"1\"\u003e6500 cable gland kit\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e6500-CBLG-01-*\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eComplete approved cable glands, plugs, and nuts for installation to the 6500 control unit\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSelection of material - stainless steel, nickel plated brass, or plastic\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e ATEX\/IECEx approved \/ II 2G 1D\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIP68\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 6500 control unit does not come with cable glands so that customers can use their own approved glands. The 6500-CBLG offers a complete set of approved cable glands for the 6500 control unit I.S. and Power sides. Selection of material allows customers to select the best cable gland for their applications.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"6500-CBLG-01-LSC","offer_id":41005633863877,"sku":"515906","price":417.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/9B9AE334-0227-4873-BC70-64C18C1E95AD_baebd8eb-67c9-4762-8601-31c4aa9026a1.png?v=1641237352"},{"product_id":"6500-cblg-01-csc","title":"6500-CBLG-01-CSC, Cable Gland Kit for 6500 Control Systems","description":"\u003cp data-mce-fragment=\"1\"\u003e6500 cable gland kit\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e6500-CBLG-01-*\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eComplete approved cable glands, plugs, and nuts for installation to the 6500 control unit\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSelection of material - stainless steel, nickel plated brass, or plastic\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e ATEX\/IECEx approved \/ II 2G 1D\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIP68\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 6500 control unit does not come with cable glands so that customers can use their own approved glands. The 6500-CBLG offers a complete set of approved cable glands for the 6500 control unit I.S. and Power sides. Selection of material allows customers to select the best cable gland for their applications.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"6500-CBLG-01-CSC","offer_id":41005633798341,"sku":"515960","price":753.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/9B9AE334-0227-4873-BC70-64C18C1E95AD_46ca7ace-9f72-410f-9a48-bc55bd518bca.png?v=1641236935"},{"product_id":"7500-mtd-bxrw-01","title":"Type Z \u0026 Ex pzc purge and pressurization system, 7500-MTD-BXRW-01","description":"\u003ch3\u003e\u003cstrong\u003e7500-MTD-BXRW-01, 7500 series type Z \u0026amp; Ex pzc purge and pressurization controller for panel and external mounting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"product-detail-header__usp-list\"\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eMust be used in conjunction with an EPV-7500-* vent\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eExternal mount, rectangular box\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eUniversal power: AC or DC\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eTouch screen display with LEDs for easy visual indication\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eEasy setup with pre-set purge programs for your application\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eAutomatic pressure compensation with digital manifold\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eRugged, corrosion-resistant housing\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eGlobal third-party approvals for Class I, II, Div. 2 and Zone 2\/22\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eManual valve, no electrical power requirement\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003ePurge and pressurization valving in one device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 7500 series panel\/external mount purge and pressurization system consists of a control unit and a 7500-MAN-MV-01 manual manifold mounted to a panel.\u003c\/p\u003e\n\u003cp\u003eThe control unit’s menu-driven touch screen display makes it easy to select pre-programmed and user-selected variables. The display has 4 LED indicators that allow users to determine system condition from a distance. See the 7500 control unit datasheet for technical data.\u003c\/p\u003e\n\u003cp\u003eThe 7500-MAN-MV-01 manifold combines in one compact housing a ball valve for purging and a needle valve for pressurizing an enclosure. The ball valve has a handle for easy actuation. To provide security and prevent tampering, the needle valve requires a slot-head screwdriver to set the enclosure pressure. See the 7500-MAN-MV-01 manifold datasheet for technical data.\u003c\/p\u003e\n\u003cp\u003eThe 7500 series system has NEC, CE Code, ATEX, CCC, and IECEx third-party certifications for Class I, II\/Div. 2 Type Z and Zone 2\/22 Ex Ppc.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"7500-MTD-BXRW-01","offer_id":41005648969925,"sku":null,"price":1690.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/418C7C68-78FA-4B5F-88E5-3C6FC87377C8.png?v=1770838908"},{"product_id":"epv-2-sa-90","title":"EPV-2-SA-90, Enclosure Protection Vent","description":"\u003ch2 class=\"alternative\" data-mce-fragment=\"1\"\u003eEnclosure Protection Vent, EPV-2-SA-90\u003c\/h2\u003e\n\u003cul id=\"productfeatures\" data-mce-fragment=\"1\"\u003e\n\u003cli\u003eSide mount, 3\/4\" (19.0 mm) vent size\u003c\/li\u003e\n\u003cli\u003eSeamless cap\u003c\/li\u003e\n\u003cli\u003eFriction free valve assembly\u003c\/li\u003e\n\u003cli\u003eSpark arresting exhaust\u003c\/li\u003e\n\u003cli\u003eCan only be purchased in conjunction with corresponding Purge system or as a replacement\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe EPV (enclosure protection vents) are self-seating, gravity controlled, low pressure relief valve designed to ventilate excessive enclosure pressures created by the Rapid Exchange® process, or the failure of the enclosure pressure control devices.\u003c\/p\u003e\n\u003cp\u003eEach vent features a seamless cap, a spark arresting (SA) style exhaust element, a friction-free valve assembly, a base, and a mounting hub. The mounting hub, along with associated pipe fittings, permits direct mounting through a round cutout on the top or side of a protected enclosure.\u003c\/p\u003e\n\u003cp\u003eThis device functions only in conjunction with Pepperl+Fuchs Bebco EPS® purge systems, to reduce the hazardous (classified) area rating within protected enclosure(s), in accordance with the NEC - NFPA 70, Article 500, NFPA 496, and ISA 12.4.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/515455_eng_1.pdf?v=1718822221\" title=\"Enclosure Protection Vent EPV-2-SA-90\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003c!----\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"EPV-2-SA-90","offer_id":41005598834885,"sku":"513148","price":386.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/b235373a_90ea38bf-775d-401c-888d-78f0cc6f903b.png?v=1604041023"},{"product_id":"epv-5500-aa-02","title":"EPV-5500-AA-02, Enclosure Protection Vent, 20 SCFM","description":"\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDrains\/Vents, 5500 Series\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan class=\"small bold\" data-mce-fragment=\"1\"\u003eModel Number:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"big bold\" data-mce-fragment=\"1\"\u003eEPV-5500-AA-02\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e- Enclosure Protection Vent, 20 SCFM\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003ch4 class=\"big bold\" data-mce-fragment=\"1\"\u003e5500 Series Information\u003c\/h4\u003e\nThe EPV‑5500 vent works with the 5500 control unit and manifold valve to form a certified purge and pressurization system for enclosures. It cannot be used alone. Vents are a required component for all pressurized enclosure systems. The EPV‑5500 functions as a pressure relief device, allowing the purge gas to exit the enclosure and includes a spark arrestor. The vent also provides a seal when enclosure is pressurized and operating. The 5500 series purge and pressurization system has NEC, CEC, ATEX and IECEx third part certifications for Class I, II\/Div. 2 and Zone 2\/22.\u003c\/div\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"EPV-5500-AA-02","offer_id":41007312404677,"sku":"515663","price":690.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/b239724a_06b42cdd-225a-4def-8637-d542dcfae2ef.png?v=1604041047"},{"product_id":"epv-5500-aa-03-enclosure-protection-vent-12-scfm","title":"EPV-5500-AA-03, Enclosure Protection Vent, 12 SCFM","description":"\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDrains\/Vents, 5500 Series\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan class=\"small bold\" data-mce-fragment=\"1\"\u003eModel Number:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"big bold\" data-mce-fragment=\"1\"\u003eEPV-5500-AA-03\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e- Enclosure Protection Vent, 12 SCFM\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong class=\"type\" data-mce-fragment=\"1\"\u003eAlternate Part Number:  \u003c\/strong\u003eBebco 515664\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003ch4 class=\"big bold\" data-mce-fragment=\"1\"\u003e5500 Series Information\u003c\/h4\u003e\nThe EPV‑5500 vent works with the 5500 control unit and manifold valve to form a certified purge and pressurization system for enclosures. It cannot be used alone. Vents are a required component for all pressurized enclosure systems. The EPV‑5500 functions as a pressure relief device, allowing the purge gas to exit the enclosure and includes a spark arrestor. The vent also provides a seal when enclosure is pressurized and operating. The 5500 series purge and pressurization system has NEC, CEC, ATEX and IECEx third part certifications for Class I, II\/Div. 2 and Zone 2\/22.\u003c\/div\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"EPV-5500-AA-03","offer_id":41005583761605,"sku":"515664","price":579.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/b239724a.png?v=1604041049"},{"product_id":"epv-5500-ss-01-enclosure-protection-vent-30-scfm","title":"EPV-5500-SS-01, Enclosure Protection Vent, 30 SCFM","description":"\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDrains\/Vents, 5500 Series\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan class=\"small bold\" data-mce-fragment=\"1\"\u003eModel Number:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"big bold\" data-mce-fragment=\"1\"\u003eEPV-5500-SS-01\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e- Enclosure Protection Vent, 30 SCFM\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003ch4 class=\"big bold\" data-mce-fragment=\"1\"\u003e5500 Series Information\u003c\/h4\u003e\nThe EPV‑5500 vent works with the 5500 control unit and manifold valve to form a certified purge and pressurization system for enclosures. It cannot be used alone. Vents are a required component for all pressurized enclosure systems. The EPV‑5500 functions as a pressure relief device, allowing the purge gas to exit the enclosure and includes a spark arrestor. The vent also provides a seal when enclosure is pressurized and operating. The 5500 series purge and pressurization system has NEC, CEC, ATEX and IECEx third part certifications for Class I, II\/Div. 2 and Zone 2\/22.\u003c\/div\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"EPV-5500-SS-01","offer_id":41007312502981,"sku":"515665","price":489.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/b239724a_81f9775a-1450-459b-9cb6-9201ffaa7a24.png?v=1604041051"},{"product_id":"epv-5500-ss-03","title":"EPV-5500-SS-03, 5500 series vent","description":"\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan class=\"small bold\" data-mce-fragment=\"1\"\u003eItem#\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"big bold\" data-mce-fragment=\"1\"\u003eEPV-5500-SS-03\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e- Enclosure Protection Vent, 12 SCFM\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDrains\/Vents, 5500 Series\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"big bold\" data-mce-fragment=\"1\"\u003e5500 Series Information\u003c\/div\u003e\nThe EPV‑5500 vent works with the 5500 control unit and manifold valve to form a certified purge and pressurization system for enclosures. It cannot be used alone. Vents are a required component for all pressurized enclosure systems. The EPV‑5500 functions as a pressure relief device, allowing the purge gas to exit the enclosure and includes a spark arrestor. The vent also provides a seal when enclosure is pressurized and operating. The 5500 series purge and pressurization system has NEC, CEC, ATEX and IECEx third part certifications for Class I, II\/Div. 2 and Zone 2\/22.\u003c\/div\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"EPV-5500-SS-03","offer_id":41007312601285,"sku":"515667","price":658.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/b239724a_5f47cca6-c985-4ba1-9d77-263a2b781850.png?v=1604041055"},{"product_id":"epv-6000-aa-01","title":"EPV-6000-AA-01 Enclosure Protection Vent, Standard","description":"\u003cp\u003eEPV-6000-AA-01, Enclosure Protection Vent, Anodized aluminum body and cap,  Standard configuration\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum enclosure size 450 ft3 (12.7 m3 )\u003c\/li\u003e\n\u003cli\u003ePressure relief vent with flow and pressure monitoring at the exhaust\u003c\/li\u003e\n\u003cli\u003eUniversal mounting in any orientation\u003c\/li\u003e\n\u003cli\u003e6000 Control Unit supports 2 vents\u003c\/li\u003e\n\u003cli\u003eDifferent vents for different applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"big bold\"\u003e6000 Series Information\u003c\/div\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe EPV‑6000 vent exhausts excess pressure from the enclosure and measures flow and pressure during operation. The 6000 series vent has a pressure transducer and thermal flow sensor that is connected to the 6000 EPCU. It is intrinsically safe through the galvanic isolation barrier within the 6000 EPCU.\u003c\/span\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"EPV-6000-AA-01","offer_id":41005601554629,"sku":"515614","price":1431.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/Screenshot2021-12-27171512.png?v=1640643328"},{"product_id":"epv-6000-ss-01-enclosure-protection-vent-anodized-aluminum-body-and-316l-stainless-steel-cap-standard-configuration","title":"EPV-6000-SS-01, Enclosure Protection Vent, Anodized aluminum body and 316L stainless steel cap,  Standard configuration","description":"\u003cdiv class=\"product-description rte\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eEPV-6000-SS-01, Enclosure Protection Vent, Anodized aluminum body and 316L stainless steel cap,  Standard configuration\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum enclosure size 450 ft3 (12.7 m3 )\u003c\/li\u003e\n\u003cli\u003ePressure relief vent with flow and pressure monitoring at the exhaust\u003c\/li\u003e\n\u003cli\u003eUniversal mounting in any orientation\u003c\/li\u003e\n\u003cli\u003e6000 Control Unit supports 2 vents\u003c\/li\u003e\n\u003cli\u003eDifferent vents for different applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"big bold\" data-mce-fragment=\"1\"\u003e6000 Series Information\u003c\/div\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe EPV‑6000 vent exhausts excess pressure from the enclosure and measures flow and pressure during operation. The 6000 series vent has a pressure transducer and thermal flow sensor that is connected to the 6000 EPCU. It is intrinsically safe through the galvanic isolation barrier within the 6000 EPCU.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"EPV-6000-SS-01","offer_id":41005601587397,"sku":"515615","price":2150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/86B452F1-8AC7-41BC-B88A-DF65A2D51FEB.png?v=1641245288"},{"product_id":"epv-6000-6500-ss-cap-only","title":"EPV-6000\/6500 SS cap only","description":"\u003cp\u003eStainless Steel Cap for EPV-6000\/6500\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"EPV-6000\/6500 SS cap only","offer_id":36629397536921,"sku":"70118175","price":166.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/70526752_23280d31-f640-4084-bcc3-59b41e14ad79.png?v=1641242468"},{"product_id":"epv-7500-aa-01-7500-series-vent-body-and-cap-6061t-aluminum-35-scfm-990-l-min-max-flow-brk-press-0-8-wc-2-mbar","title":"EPV-7500-AA-01, 7500 Series vent, 7500 series purge and pressurization system vent, aluminum body and cap","description":"\u003ch4\u003e\u003cstrong\u003eEPV-7500-AA-01, 7500 Series vent, 7500 series purge and pressurization system vent, aluminum body and cap\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e7500 series purge and pressurization system vent, aluminum body and cap\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMust be used in conjunction with a 7500-01-AA* or 7500-MTD-* purge and pressurization control unit\u003c\/li\u003e\n\u003cli\u003eLow cost, universal mounting, easy to use\u003c\/li\u003e\n\u003cli\u003eNot gravity dependent\u003c\/li\u003e\n\u003cli\u003eVarious enclosure protection vents for different applications\u003c\/li\u003e\n\u003cli\u003eRugged, corrosion-resistant housing\u003c\/li\u003e\n\u003cli\u003eMechanical with no cables\u003c\/li\u003e\n\u003cli\u003eGlobal third-party approvals for Class I, II, Div. 2 and Zone 2\/22\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 7500 series purge and pressurization system consists of a control unit, an enclosure protection vent, and a manual or automatic manifold. The control unit’s menu-driven touch screen display makes it easy to select pre-programmed and user-selected variables. The display has 4 LED indicators that allow users to determine system condition from a distance. A digital manifold system such as the 5500-MAN-... can be used to make the 7500 a fully automatic system. Enclosure pressure and leakage are monitored. If a loss in enclosure pressure occurs, the solenoid valve engages to restore the defined pressure settings and\/or trigger a pressure drop alarm. The 7500 series system has NEC, CEC, ATEX, and IECEx third-party certifications for Class I, II\/Div. 2 Type Z and Zone 2\/22 Ex pzc.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"EPV-7500-AA-01","offer_id":41005602308293,"sku":"516145","price":698.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/70526657.jpg?v=1603927386"},{"product_id":"0-1-0-magn-indicator-w-face-p","title":"0-1.0 MAGN. INDICATOR W\/FACE PL","description":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eLATE(195160-00)\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e0-1.0 MAGN. INDICATOR W\/FACE P\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003ePepperl Fuchs Item Number: 510024\u003c\/span\u003e\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"0-1.0 MAGN. INDICATOR W\/FACE P","offer_id":36629425422489,"sku":"510024","price":179.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/70526752_81240377-64f7-4a2c-858f-defeda3a545a.png?v=1642025153"},{"product_id":"kfd0-cs-ex1-50p","title":"Repeater KFD0-CS-Ex1.50P","description":"\u003ch1\u003eKFD0-CS-Ex1.50P, Repeater \u003c\/h1\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (loop powered)\u003c\/li\u003e\n\u003cli\u003eCurrent input\/output 4 mA ... 20 mA\u003c\/li\u003e\n\u003cli\u003etransmitter power supply\u003c\/li\u003e\n\u003cli\u003eAccuracy 0.1 %\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection\u003c\/li\u003e\n\u003cli\u003eSIL 2 (SC 3) acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device can be used as a repeater or transmitter power supply for 2-wire transmitters.\u003c\/p\u003e\n\u003cp\u003eThis device is loop powered. No additional power supply has to be connected.\u003c\/p\u003e\n\u003cp\u003eUse the technical data to verify that proper voltage is available to the field devices.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD0-CS-Ex1.50P","offer_id":41005617709253,"sku":"294964","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/2B93D854-29E5-43D7-A17B-E3D554371288.png?v=1657031362"},{"product_id":"kfd0-cs-ex2-51p-current-driver-repeater-isolated-barrier-for-intrinsic-safety-applications","title":"KFD0-CS-EX2.51P, Current Driver\/Repeater","description":"\u003ch3\u003eCurrent Driver\/Repeater KFD0-CS-Ex2.51P\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (loop powered)\u003c\/li\u003e\n\u003cli\u003eCurrent input\/output 0 mA ... 40 mA\u003c\/li\u003e\n\u003cli\u003eI\/P or transmitter power supply\u003c\/li\u003e\n\u003cli\u003eAccuracy 1 %\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection\u003c\/li\u003e\n\u003cli\u003eSIL 2 (SC 3) acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications. The device transfers DC signals of fire alarms and smoke alarms from the hazardous area to the non-hazardous area. The device can also be used to control I\/P converters, valves, indicators, and audible alarms. A reverse polarity protection prevents damage to the device caused by faulty wiring. The device is loop powered. From the control side no additional power supply has to be connected. Use the technical data to verify that proper voltage is available to the field devices.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD0-CS-EX2.51P","offer_id":36629438365849,"sku":"294987","price":485.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/CFB093DC-B412-4B74-852D-6270BC600ABA_ba04a5c8-0d27-49aa-8ada-f50b379c81d5.png?v=1641303996"},{"product_id":"kfd2-scd2-ex2-lk-smart-current-driver-isolated-barrier-for-intrinsic-safety-applications","title":"KFD2-SCD2-EX2.LK, SMART Current Driver, Isolated barrier for intrinsic safety applications","description":"\u003ch4\u003eSMART Current Driver KFD2-SCD2-Ex2.LK\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eCurrent output up to 650 Ω load\u003c\/li\u003e\n\u003cli\u003eHART I\/P and valve positioner\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eAccuracy 0.1 %\u003c\/li\u003e\n\u003cli\u003eSIL 2 (SC 3) acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications. The device drives SMART I\/P converters, electrical valves, and positioners in hazardous areas. Digital signals are superimposed on the analog values at the field side or control side and are transferred bi-directionally. Current transferred across the DC\/DC converter is repeated at terminals 1, 2 and 4, 5. Terminals 2, 3 and 5, 6 are used when no short circuit detection is required. An open or short field circuit presents a high impedance to the control side to allow alarm conditions to be monitored by the control system. If the HART communication resistance in the loop is too low, the internal resistance can be used. Test sockets for the connection of HART communicators are integrated into the terminals of the device. A fault is signalized by LEDs and a separate collective error message output.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD2-SCD2-EX2.LK","offer_id":36629442461849,"sku":"295089","price":730.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/188E104D-5E28-440B-A715-77F72C19E5B1.png?v=1641304413"},{"product_id":"kfd2-vr2-ex1-50m","title":"KFD2-VR2-EX1.50M, Voltage Repeater","description":"\u003ch1 class=\"product-detail-header__headline\"\u003e\u003cspan\u003eVoltage Repeater, KFD2-VR2-EX1.50M\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul class=\"product-detail-header__usp-list\"\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eVoltage input 0 mV ... ± 50 mV\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eVoltage output 0 mV ... ± 50 mV\u003c\/li\u003e\n\u003cli class=\"product-detail-header__usp-list-item\"\u003eSelectable up\/downscale sensor breakage detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eIt transfers low voltage signals from load cells, strain gauges, operational amplifiers, and inductive oscillation sensors located in hazardous areas to safe areas.\u003c\/p\u003e\n\u003cp\u003eThe input voltage of the terminals 4 and 5 is transferred to the terminals 7 and 8.\u003c\/p\u003e\n\u003cp\u003eThe input, output, and power supply are galvanically isolated from each other. Upscale or downscale lead breakage monitoring is selectable via switches located on the front panel of the device.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote:\u003c\/em\u003eThis unit requires three minutes after power-up to reach the accuracy cited in the technical data.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD2-VR2-Ex1.50M","offer_id":41005620035781,"sku":"181951","price":548.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/1E8C0DB4-4CE5-455B-910E-72920ECCD895.png?v=1766526659"},{"product_id":"kcd2-stc-ex1","title":"SMART Transmitter Power Supply KCD2-STC-Ex1","description":"\u003ch1 class=\"alternative\"\u003eSMART Transmitter Power Supply KCD2-STC-Ex1\u003c\/h1\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eInput for 2-wire SMART transmitters and current sources\u003c\/li\u003e\n\u003cli\u003eOutput for 4 mA ... 20 mA or 1 V ... 5 V\u003c\/li\u003e\n\u003cli\u003eHousing width 12.5 mm\u003c\/li\u003e\n\u003cli\u003eSIL 2 (SC 3) acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e This isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device supplies 2-wire SMART transmitters in a hazardous area, and can also be used with 2-wire SMART current sources.\u003c\/p\u003e\n\u003cp\u003eIt transfers the analog input signal to the safe area as an isolated current value.\u003c\/p\u003e\n\u003cp\u003eDigital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally.\u003c\/p\u003e\n\u003cp\u003eSelectable output of current source, sink mode, or voltage output is available via DIP switches.\u003c\/p\u003e\n\u003cp\u003eIf the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 6 and 8 can be used.\u003c\/p\u003e\n\u003cp\u003eTest sockets for the connection of HART communicators are integrated into the terminals of the device.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-get6{background-color:#409cff;border-color:inherit;color:#FFF;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:middle}\n.tg .tg-jnh8{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:top}\n.tg .tg-h1e6{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:center;vertical-align:top}\n.tg .tg-9lfx{background-color:#ebf5ff;border-color:inherit;color:#425563;font-weight:bold;text-align:left;vertical-align:middle}\n.tg .tg-lvgc{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:middle}\n.tg .tg-9bam{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:center;vertical-align:middle}\n--\u003e\u003c\/style\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KCD2-STC-Ex1","offer_id":41005617479877,"sku":"316910","price":378.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/571F3B23-7853-4F30-8F45-E51D15035DA5.png?v=1650477853"},{"product_id":"kfd2-stc5-ex2-smart-transmitter-power-supply","title":"KFD2-STC5-Ex2, SMART Transmitter Power Supply","description":"\u003ch4 class=\"alternative\" data-mce-fragment=\"1\"\u003eSMART Transmitter Power Supply KFD2-STC5-Ex2\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eInput 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003eOutput 0\/4 mA ... 20 mA current sink\/current source\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eSIL 2 (SC 3) acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device supplies 2-wire and 3-wire SMART transmitters, and can also be used with 2-wire SMART current sources.\u003c\/p\u003e\n\u003cp\u003eIt transfers the analog input signal to the safe area as an isolated current value.\u003c\/p\u003e\n\u003cp\u003eDigital signals may be superimposed on the input signal in the hazardous or non-hazardous area and are transferred bi-directionally.\u003c\/p\u003e\n\u003cp\u003eThe device provides a sink mode or a source mode output on the safe area terminals.\u003c\/p\u003e\n\u003cp\u003eThe device has an internal resistor. Use this resistor if the HART communication resistance in the control circuit is too low.\u003c\/p\u003e\n\u003cp\u003eTest sockets for the connection of HART communicators are integrated into the terminals of the device.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD2-STC5-Ex2","offer_id":41005619445957,"sku":"203645","price":609.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/D532F380-A1A8-42A4-A776-3A06B518216E_42820334-a3a5-49a3-942a-65e1bf432432.png?v=1641320873"},{"product_id":"kfd0-cs-ex1-54","title":"KFD0-CS-Ex1.54, Repeater","description":"\u003ch3\u003eRepeater, KFD0-CS-Ex1.54\u003c\/h3\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 VDC supply  (loop powered)\u003c\/li\u003e\n\u003cli\u003eSMART fire alarm input\u003c\/li\u003e\n\u003cli\u003eCurrent input 1 mA ... 20 mA\u003c\/li\u003e\n\u003cli\u003eUp to SIL 3 acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications. It provides control and signal transfer for SMART compatible fire and smoke alarm transmitters inside hazardous areas.\u003c\/p\u003e\n\u003cp\u003eDigital signals may be superimposed on the analog values in the hazardous or safe area and are transferred bidirectionally.\u003c\/p\u003e\n\u003cp\u003eThe fall time of the digital signal must be less than 50 μs, the current in the hazardous area must be bigger than 1 mA.\u003c\/p\u003e\n\u003cp\u003eSince this isolator is loop-powered, use the technical data to verify that proper voltage is available to the field devices.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD0-CS-EX1.54","offer_id":41005617774789,"sku":"70185883","price":345.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/95611CAE-F697-4572-94C8-2388FA813224.png?v=1758730872"},{"product_id":"kcd2-ut2-ex1","title":"Universal Temperature Converter KCD2-UT2-Ex1","description":"\u003ch1 class=\"alternative\" data-mce-fragment=\"1\"\u003eUniversal Temperature Converter KCD2-UT2-Ex1\u003c\/h1\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eThermocouple, RTD, potentiometer or voltage input\u003c\/li\u003e\n\u003cli\u003eCurrent output 0\/4 mA ... 20 mA\u003c\/li\u003e\n\u003cli\u003eSink or source mode\u003c\/li\u003e\n\u003cli\u003eConfigurable by PACTware\u003c\/li\u003e\n\u003cli\u003eLine fault (LFD) and sensor burnout detection\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 acc. to IEC 61508\/IEC 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device converts RTD input signals or thermocouple input signals in the hazardous area to 0\/4 mA ... 20mA signals in the safe area.\u003c\/p\u003e\n\u003cp\u003eThe removable terminal block KC-CJC-** is available for thermocouples when internal cold junction compensation is desired.\u003c\/p\u003e\n\u003cp\u003eA fault is indicated by an LED and by user-configured fault indication outputs.\u003c\/p\u003e\n\u003cp\u003eIf the device is operated via Power Rail, additionally a collective error message is available.\u003c\/p\u003e\n\u003cp\u003eThe device is easily configured by the use of the PACTware configuration software.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KCD2-UT2-Ex1","offer_id":41005617610949,"sku":"70156489","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/956A4AD2-231E-43E4-B652-C74F67D1FA8A.png?v=1650480724"},{"product_id":"kcd2-scd-ex1-smart-current-driver-isolated-barrier-for-intrinsic-safety-applications","title":"KCD2-SCD-Ex1, SMART Current Driver, Isolated barrier for intrinsic safety applications","description":"\u003ch4\u003eSMART Current Driver, KCD2-SCD-Ex1\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eCurrent output up to 650 Ω load\u003c\/li\u003e\n\u003cli\u003eHART I\/P and valve positioner\u003c\/li\u003e\n\u003cli\u003eLead breakage monitoring\u003c\/li\u003e\n\u003cli\u003eHousing width 12.5 mm\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 (SC 3) acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device repeats the input signal from a control system to drive SMART I\/P converters, electrical valves, and positioners located in a hazardous area.\u003c\/p\u003e\n\u003cp\u003eDigital signals are superimposed on the analog values at the field side or control side and are transferred bi-directionally.\u003c\/p\u003e\n\u003cp\u003eThe current is transferred via a DC\/DC converter and repeated at the output terminals.\u003c\/p\u003e\n\u003cp\u003eAn open field circuit presents a high impedance to the control side to allow alarm conditions to be monitored by the control system.\u003c\/p\u003e\n\u003cp\u003eTest sockets for the connection of HART communicators are integrated into the terminals of the device.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KCD2-SCD-EX1","offer_id":36629449605273,"sku":"70150440","price":525.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/5165F1EF-F64E-413B-B068-572029D9D34E.png?v=1641311966"},{"product_id":"kfd2-stc5-ex1-smart-transmitter-power-supply","title":"KFD2-STC5-Ex1, SMART Transmitter Power Supply","description":"\u003cp\u003eSMART Transmitter Power Supply KFD2-STC5-Ex1\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eInput 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003eOutput 0\/4 mA ... 20 mA current sink\/current source\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eSIL 2 (SC 3) acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications. The device supplies 2-wire and 3-wire SMART transmitters, and can also be used with 2-wire SMART current sources. It transfers the analog input signal to the safe area as an isolated current value. Digital signals may be superimposed on the input signal in the hazardous or non-hazardous area and are transferred bi-directionally. The device provides a sink mode or a source mode output on the safe area terminals. The device has an internal resistor. Use this resistor if the HART communication resistance in the control circuit is too low. Test sockets for the connection of HART communicators are integrated into the terminals of the device.\u003c\/p\u003e\n\u003cp\u003eThe device supports the following SMART protocols:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHART\u003c\/li\u003e\n\u003cli\u003eBRAIN\u003c\/li\u003e\n\u003cli\u003eFoxboro\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD2-STC5-Ex1","offer_id":36629449965721,"sku":"70124109","price":405.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/D532F380-A1A8-42A4-A776-3A06B518216E.png?v=1641314305"},{"product_id":"kfd2-crg2-ex1-d","title":"Transmitter Power Supply KFD2-CRG2-Ex1.D","description":"\u003ch4\u003eKFD2-CRG2-Ex1.D, Transmitter Power Supply \u003c\/h4\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device supplies 2-wire and 3-wire transmitters, and can also be used with current sources.\u003c\/p\u003e\n\u003cp\u003eTwo relays and an active 0\/4 mA ... 20 mA current source are available as outputs. The relay contacts and the current output can be integrated in security-relevant circuits. The current output is easily scaled.\u003c\/p\u003e\n\u003cp\u003eOn the display the measured value can be indicated in various physical units.\u003c\/p\u003e\n\u003cp\u003eThe device is easily configured by the use of keypad or with the PACTware configuration software.\u003c\/p\u003e\n\u003cp\u003eThe input has a line fault detection.\u003c\/p\u003e\n\u003cp\u003eA fault is signalized by LEDs acc. to NAMUR NE44 and a separate collective error message output.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD2-CRG2-EX1.D","offer_id":41005618397381,"sku":"255620","price":820.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/3EA7DED2-B00A-4480-8091-8BA94157A571.png?v=1675206638"},{"product_id":"kfd2-stc4-ex1-smart-transmitter-power-supply","title":"KFD2-STC4-Ex1, SMART Transmitter Power Supply","description":"\u003ch1 class=\"alternative\" data-mce-fragment=\"1\"\u003e\u003c\/h1\u003e\n\u003ch1\u003e SMART Transmitter Power Supply, KFD2-STC4-Ex1\u003c\/h1\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eInput 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003eOutput 0\/4 mA ... 20 mA\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device supplies 2-wire and 3-wire SMART transmitters in a hazardous area, and can also be used with 2-wire SMART current sources.\u003c\/p\u003e\n\u003cp\u003eIt transfers the analog input signal to the safe area as an isolated current value.\u003c\/p\u003e\n\u003cp\u003eDigital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally.\u003c\/p\u003e\n\u003cp\u003eIf the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 8 and 9 can be used.\u003c\/p\u003e\n\u003cp\u003eTest sockets for the connection of HART communicators are integrated into the terminals of the device.\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\n  font-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\n  font-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-q35k{background-color:#ebf5ff;border-color:inherit;color:#343434;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-jnh8{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:top}\n.tg .tg-c3ow{border-color:inherit;text-align:center;vertical-align:top}\n.tg .tg-h1e6{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:center;vertical-align:top}\n.tg .tg-wqna{background-color:#409cff;border-color:inherit;color:#ffffff;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:top}\n.tg .tg-riw3{background-color:#ebf5ff;border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-iblv{background-color:#EBF5FF;border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-0pky{border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-sa29{background-color:#ebf5ff;border-color:inherit;text-align:center;vertical-align:top}\n.tg .tg-lvgc{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:middle}\n.tg .tg-05q9{background-color:#ebf5ff;border-color:inherit;font-size:15px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-k5ap{background-color:#EBF5FF;border-color:inherit;text-align:center;vertical-align:top}\n.tg .tg-h6w4{border-color:inherit;font-size:15px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-ctnh{background-color:#ebf5ff;border-color:inherit;color:#000000;font-size:15px;font-weight:bold;text-align:left;\n  vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-wqna\" colspan=\"2\"\u003eProduct Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" colspan=\"2\"\u003eInput 0\/4 mA ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" colspan=\"2\"\u003eOutput 0\/4 mA ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eGeneral specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eSignal type\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eAnalog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eFunctional safety related parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eSafety Integrity Level (SIL)\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eSIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eSupply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-iblv\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-iblv\"\u003ePower Rail or terminals 14+, 15-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eRated voltage\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e20 ... 35 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eRipple\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003ewithin the supply tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003ePower dissipation\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e1.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e1.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eInput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eConnection side\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003efield side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eterminals 1+, 2-, 3 or 5-, 6+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eInput signal\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e0\/4 ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eVoltage drop\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e≤ 2.4 V at 20 mA (terminals 5, 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eInput resistance\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e≤ 64 Ω terminals 2-, 3 ; ≤ 500 Ω terminals 1+, 3 (250 Ω load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eAvailable voltage\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e≥ 16 V at 20 mA, terminals 1+, 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eOutput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eConnection side\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003econtrol side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eterminals 7-, 8+, 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eLoad\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e0 ... 800 Ω at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eOutput signal\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e0\/4 ... 20 mA (overload \u0026gt; 25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eRipple\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003emax. 50 µA rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eTransfer characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" rowspan=\"2\"\u003eDeviation\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eat 20 °C (68 °F), 0\/4 ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003e≤ 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eInfluence of ambient temperature\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e0.25 µA\/K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003efield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 7.5 kHz (-3 dB)\u003cbr\u003esafe area to hazardous area: bandwidth with 0.5 Vpp signal 0.3 ... 7.5 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eSettling time\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e200 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eRise time\/fall time\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e20 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eGalvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eOutput\/power supply\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003efunctional insulation, rated insulation voltage 50 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003e\u003cspan\u003eOutput\/Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e\u003cspan\u003efunctional insulation, rated insulation voltage 50 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eIndicators\/settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDisplay elements\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eLabeling\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003espace for labeling at the front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eDirective conformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" colspan=\"2\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eDirective 2014\/30\/EU\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eEN 61326-1:2013 (industrial locations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eConformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eNE 21:2011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eIEC 60529:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eProtection against electrical shock\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eUL 61010-1:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eAmbient conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003e-20 ... 60 °C (-4 ... 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eMechanical specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003escrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eMass\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eapprox. 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eMounting\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eon 35 mm DIN mounting rail acc. to EN 60715:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eData for application in connection with hazardous areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-05q9\"\u003eEU-type examination certificate\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eBAS 99 ATEX 7025 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eMarking\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e\n\u003cimg src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" width=\"17\" height=\"16\"\u003e II (1)G [Ex ia Ga] IIC , \u003cimg src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" width=\"17\" height=\"16\"\u003e II (1)D [Ex ia Da] IIIC , \u003cimg src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" width=\"17\" height=\"16\"\u003e I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eInput\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-05q9\" colspan=\"2\"\u003eSupply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-k5ap\"\u003eMaximum safe voltage\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e250 V (Attention! The rated voltage can be lower.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h6w4\"\u003eEquipment\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eterminals 1+, 3-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eVoltage Uo\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e25.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eCurrent Io\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e86.8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003ePower Po\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e551 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h6w4\"\u003eEquipment\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eterminals 2-, 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eCurrent Io\/Current Ii\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e74 mA \/ 115 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eCurrent Ii\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e115 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eVoltage Uo\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e3.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eCurrent Io\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e74 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003ePower Po\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e64 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h6w4\"\u003eEquipment\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eterminals 1+, 2 \/ 3-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eVoltage Ui\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eCurrent Ii\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e115 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eVoltage Uo\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e25.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eCurrent Io\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e115 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003ePower Po\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e584 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h6w4\"\u003eEquipment\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eterminals 5-, 6+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eVoltage Ui\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eCurrent Ii\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e115 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eVoltage Uo\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e8.7 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eCurrent Io\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h6w4\" colspan=\"2\"\u003eOutput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eMaximum safe voltage\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e250 V (Attention! The rated voltage can be lower.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-05q9\"\u003eCertificate\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eTÜV 99 ATEX 1499 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eMarking\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e\n\u003cimg src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" width=\"17\" height=\"16\"\u003eII 3G Ex nA II T4 [device in zone 2]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ctnh\" colspan=\"2\"\u003eGalvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eInput\/Output\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003esafe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eInput\/power supply\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003esafe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-05q9\" colspan=\"2\"\u003eDirective conformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eDirective 2014\/34\/EU\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eInternational approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-05q9\" colspan=\"2\"\u003eUL approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eControl drawing\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e116-0428 (cULus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" rowspan=\"2\"\u003eIECEx approval\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eIECEx BAS 04.0015X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eIECEx CML 15.0055X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" rowspan=\"2\"\u003eApproved for\u003c\/td\u003e\n\u003ctd class=\"tg-q35k\"\u003e[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eEx nA IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eGeneral information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eSupplementary information\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see - www.control-automation.com\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eAccessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\" rowspan=\"3\"\u003eOptional accessories\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e- power feed module KFD2-EB2(.R4A.B)(.SP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003e- universal power rail UPR-03(-M)(-S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003e- profile rail K-DUCT-BU(-UPR-03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD2-STC4-Ex1","offer_id":41005641105605,"sku":"283672","price":487.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/E8382272-8F0F-477C-AEA6-D3B4D6931AB5.png?v=1641557999"},{"product_id":"kfd2-stc4-ex1-2o-smart-transmitter-power-supply","title":"KFD2-STC4-Ex1.2O, SMART Transmitter Power Supply","description":"\u003ch4 class=\"alternative\" data-mce-fragment=\"1\"\u003eSMART Transmitter Power Supply, KFD2-STC4-Ex1.2O\u003c\/h4\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eInput 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003eSignal splitter (1 input and 2 outputs)\u003c\/li\u003e\n\u003cli\u003eDual output 0\/4 mA ... 20 mA\u003c\/li\u003e\n\u003cli\u003eTerminal blocks with test sockets\u003c\/li\u003e\n\u003cli\u003eUp to SIL 3 acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device supplies 2-wire and 3-wire SMART transmitters in a hazardous area, and can also be used with 2-wire SMART current sources.\u003c\/p\u003e\n\u003cp\u003eIt transfers the analog input signal to the safe area as an isolated current value.\u003c\/p\u003e\n\u003cp\u003eDigital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally.\u003c\/p\u003e\n\u003cp\u003eIf the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 8 and 9 can be used.\u003c\/p\u003e\n\u003cp\u003eTest sockets for the connection of HART communicators are integrated into the terminals of the device.\u003c\/p\u003e\n\u003cp\u003eThe device supports the following SMART protocols:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHART\u003c\/li\u003e\n\u003cli\u003eBRAIN\u003c\/li\u003e\n\u003cli\u003eFoxboro\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD2-STC4-Ex1.2O","offer_id":41005619282117,"sku":"283674","price":705.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/B3CD887E-24B2-4302-B6E7-D966A6E50187.png?v=1641560439"},{"product_id":"kfd2-stc4-ex1-2o-y1-smart-transmitter-power-supply-output-current-sink","title":"KFD2-STC4-Ex1.2O-Y1, SMART Transmitter Power Supply, Output Current Sink","description":"\u003ch4 class=\"alternative\" data-mce-fragment=\"1\"\u003eSMART Transmitter Power Supply, Output Current Sink, KFD2-STC4-Ex1.2O-Y1\u003c\/h4\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eInput 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003eSignal splitter (1 input and 2 outputs)\u003c\/li\u003e\n\u003cli\u003eDual output 0\/4 mA ... 20 mA, current sink\u003c\/li\u003e\n\u003cli\u003eTerminal blocks with test sockets\u003c\/li\u003e\n\u003cli\u003eUp to SIL 3 acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003cbr\u003e\u003cbr\u003eThe device supplies 2-wire and 3-wire SMART transmitters in a hazardous area, and can also be used with 2-wire SMART current sources.\u003cbr\u003e\u003cbr\u003eIt transfers the analog input signal to the safe area as two isolated current values.\u003cbr\u003e\u003cbr\u003eDigital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally.\u003cbr\u003e\u003cbr\u003eIt is designed to provide a sink mode output on the safe area terminals.\u003cbr\u003e\u003cbr\u003eIf the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 8 and 9 can be used.\u003cbr\u003e\u003cbr\u003eTest sockets for the connection of HART communicators are integrated into the terminals of the device.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD2-STC4-Ex1.2O-Y1","offer_id":41005619314885,"sku":"283687","price":624.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/225E9DAA-9129-42C2-B7BE-541B70825416.png?v=1641562872"},{"product_id":"kfd2-stc4-ex1-h-smart-transmitter-power-supply","title":"KFD2-STC4-Ex1.H, SMART Transmitter Power Supply","description":"\u003ch4 class=\"alternative\" data-mce-fragment=\"1\"\u003eSMART Transmitter Power Supply, KFD2-STC4-Ex1.H\u003c\/h4\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eInput 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003eOutput 0\/4 mA ... 20 mA\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eHigh field voltage 17.6 V DC\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003cbr\u003e\u003cbr\u003eThe device supplies 2-wire and 3-wire SMART transmitters with higher output voltage in a hazardous area, and can also be used with 2-wire SMART current sources.\u003cbr\u003e\u003cbr\u003eIt transfers the analog input signal to the safe area as an isolated current value.\u003cbr\u003e\u003cbr\u003eDigital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally.\u003cbr\u003e\u003cbr\u003eIf the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 8 and 9 can be used.\u003cbr\u003e\u003cbr\u003eTest sockets for the connection of HART communicators are integrated into the terminals of the device.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD2-STC4-Ex1.H","offer_id":41005619380421,"sku":"283692","price":430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/52B99A46-9B2D-41C0-A5BA-22418B83707A.png?v=1641563814"},{"product_id":"kfd2-stc4-ex2-smart-transmitter-power-supply","title":"KFD2-STC4-Ex2, SMART Transmitter Power Supply","description":"\u003ch4 class=\"alternative\"\u003eSMART Transmitter Power Supply, KFD2-STC4-Ex2\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eInput 2-wire SMART transmitters\u003c\/li\u003e\n\u003cli\u003eOutput 0\/4 mA ... 20 mA\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device supplies 2-wire SMART transmitters in a hazardous area.\u003c\/p\u003e\n\u003cp\u003eIt transfers the analog input signal to the safe area as an isolated current value.\u003c\/p\u003e\n\u003cp\u003eDigital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally.\u003c\/p\u003e\n\u003cp\u003eIf the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 8 and 9 can be used.\u003c\/p\u003e\n\u003cp\u003eTest sockets for the connection of HART communicators are integrated into the terminals of the device.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\n  font-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\n  font-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-q35k{background-color:#ebf5ff;border-color:inherit;color:#343434;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-jnh8{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:top}\n.tg .tg-xpdm{background-color:#EBF5FF;text-align:center;vertical-align:top}\n.tg .tg-h1e6{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:center;vertical-align:top}\n.tg .tg-wqna{background-color:#409cff;border-color:inherit;color:#ffffff;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:top}\n.tg .tg-0pky{border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-riw3{background-color:#ebf5ff;border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-iblv{background-color:#EBF5FF;border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-lvgc{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:middle}\n.tg .tg-sa29{background-color:#ebf5ff;border-color:inherit;text-align:center;vertical-align:top}\n.tg .tg-bk4u{background-color:#ebf5ff;border-color:inherit;font-size:13px;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n.tg .tg-nru3{background-color:#ebf5ff;border-color:inherit;color:#000000;font-size:14px;text-align:left;vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\n  font-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\n  font-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-q35k{background-color:#ebf5ff;border-color:inherit;color:#343434;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-jnh8{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:top}\n.tg .tg-xpdm{background-color:#EBF5FF;text-align:center;vertical-align:top}\n.tg .tg-h1e6{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:center;vertical-align:top}\n.tg .tg-wqna{background-color:#409cff;border-color:inherit;color:#ffffff;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:top}\n.tg .tg-riw3{background-color:#ebf5ff;border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-iblv{background-color:#EBF5FF;border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-lvgc{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:middle}\n.tg .tg-sa29{background-color:#ebf5ff;border-color:inherit;text-align:center;vertical-align:top}\n.tg .tg-bk4u{background-color:#ebf5ff;border-color:inherit;font-size:13px;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n.tg .tg-nru3{background-color:#ebf5ff;border-color:inherit;color:#000000;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-0pky{border-color:inherit;text-align:left;vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\n  font-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\n  font-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-q35k{background-color:#ebf5ff;border-color:inherit;color:#343434;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-jnh8{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:top}\n.tg .tg-xpdm{background-color:#EBF5FF;text-align:center;vertical-align:top}\n.tg .tg-h1e6{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:center;vertical-align:top}\n.tg .tg-wqna{background-color:#409cff;border-color:inherit;color:#ffffff;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:top}\n.tg .tg-riw3{background-color:#ebf5ff;border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-iblv{background-color:#EBF5FF;border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n.tg .tg-lvgc{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:middle}\n.tg .tg-sa29{background-color:#ebf5ff;border-color:inherit;text-align:center;vertical-align:top}\n.tg .tg-bk4u{background-color:#ebf5ff;border-color:inherit;font-size:13px;text-align:left;vertical-align:top}\n.tg .tg-nru3{background-color:#ebf5ff;border-color:inherit;color:#000000;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-0pky{border-color:inherit;text-align:left;vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-wqna\" colspan=\"2\"\u003eProduct Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" colspan=\"2\"\u003eInput 0\/4 mA ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" colspan=\"2\"\u003eOutput 0\/4 mA ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eGeneral specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eSignal type\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eAnalog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eFunctional safety related parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eSafety Integrity Level (SIL)\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eSIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eSupply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-iblv\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-iblv\"\u003ePower Rail or terminals 14+, 15-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eRated voltage\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e20 ... 35 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eRipple\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003ewithin the supply tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003ePower dissipation\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e1.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003emax. 2.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eInput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eConnection side\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003efield side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eterminals 1+, 3-; 4+, 6-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eInput signal\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e0\/4 ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eAvailable voltage\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e16 V at 20 mA, terminals 1+, 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eOutput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eConnection side\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003econtrol side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eterminals 7-, 8+; 10-, 11+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eLoad\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e0 ... 550 Ω at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eOutput signal\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e0\/4 ... 20 mA (overload \u0026gt; 25 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eRipple\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003emax. 50 µA rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eTransfer characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" rowspan=\"2\"\u003eDeviation\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eat 20 °C (68 °F), 0\/4 ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0lax\"\u003e≤ 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eInfluence of ambient temperature\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e0.25 µA\/K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003efield side into the control side: band width with 1 Vpp signal 0 ... 7.5 kHz (-3 dB)\u003cbr\u003esafe area to hazardous area: band width with 1 VSS signal 0.3 ... 7.5 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eSettling time\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e200 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eRise time\/fall time\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e20 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eGalvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eOutput\/power supply\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003efunctional insulation, rated insulation voltage 50 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eOutput\/Output\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003efunctional insulation, rated insulation voltage 50 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eIndicators\/settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDisplay elements\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eLabeling\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003espace for labeling at the front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eDirective conformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" colspan=\"2\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDirective 2014\/30\/EU\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eEN 61326-1:2013 (industrial locations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eConformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eNE 21:2011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eIEC 60529:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eProtection against electrical shock\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eUL 61010-1:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eAmbient conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003e-20 ... 60 °C (-4 ... 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003escrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eMass\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eMounting\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eon 35 mm DIN mounting rail acc. to EN 60715:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eData for application in connection with hazardous areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eEU-type examination certificate\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eBAS 99 ATEX 7025 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eMarking\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e\n\u003cimg alt=\"Ex-Hexagon\" src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\"\u003e\u003cspan\u003e II (1)G [Ex ia Ga] IIC , \u003c\/span\u003e\u003cimg alt=\"Ex-Hexagon\" src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\"\u003e\u003cspan\u003e II (1)D [Ex ia Da] IIIC , \u003c\/span\u003e\u003cimg alt=\"Ex-Hexagon\" src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\"\u003e\u003cspan\u003e I (M1) [Ex ia Ma] I\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eInput\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e25.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eCurrent\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e93 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e0.586 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-bk4u\" colspan=\"2\"\u003eSupply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-xpdm\"\u003eMaximum safe voltage\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003e250 V (Attention! The rated voltage can be lower.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eCertificate\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eTÜV 99 ATEX 1499 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eMarking\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e\n\u003cimg alt=\"Ex-Hexagon\" src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\"\u003e\u003cspan\u003e II 3G Ex nA II T4 [device in zone 2]\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-nru3\" colspan=\"2\"\u003eGalvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eInput\/Output\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003esafe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eInput\/power supply\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003esafe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" colspan=\"2\"\u003eDirective conformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eDirective 2014\/34\/EU\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eInternational approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" colspan=\"2\"\u003eUL approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eControl drawing\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e116-0428 (cULus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eIECEx approval\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eIECEx BAS 04.0015X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\" rowspan=\"2\"\u003eApproved for\u003c\/td\u003e\n\u003ctd class=\"tg-q35k\"\u003e[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eEx nA IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eGeneral information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eSupplementary information\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see - www.control-automation.com\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD2-STC4-Ex2","offer_id":41005641138373,"sku":"283699","price":695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/747F6D31-533A-4CCE-8DC7-A3F38134AB2A.png?v=1641564382"},{"product_id":"hic2441","title":"HiC2441, SMART Universal Barrier","description":"\u003ch3 class=\"alternative\" data-mce-fragment=\"1\"\u003eSMART Universal Barrier, HiC2441\u003c\/h3\u003e\n\u003cul id=\"productfeatures\" data-mce-fragment=\"1\"\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (bus powered)\u003c\/li\u003e\n\u003cli\u003eAnalog input, digital input,\u003cbr\u003eanalog output, digital output\u003c\/li\u003e\n\u003cli\u003eNo configuration required, device is self-adapting\u003c\/li\u003e\n\u003cli\u003eHART transparency\u003c\/li\u003e\n\u003cli\u003eLow power dissipation\u003c\/li\u003e\n\u003cli\u003e3-way isolation\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 acc. to IEC\/EN 61508\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device can transfer the following signals:\u003cbr\u003e- as an analog input: 0\/4 mA ... 20 mA\u003cbr\u003e- as an analog output: 0\/4 mA ... 20 mA\u003cbr\u003e- as a digital input: signals from NAMUR sensors or dry contacts\u003cbr\u003e- as a digital output: max. 45 mA\u003c\/p\u003e\n\u003cp\u003eThe device requires no configuration and adapts itself automatically to the function of the active input\/output of the connected process control system.\u003c\/p\u003e\n\u003cp\u003eThe device permits the bi-directional pass-through of the HART communication.\u003c\/p\u003e\n\u003cp\u003eThe device is designed primarily for use with universal I\/O cards (e. g. Honeywell Universal Process IO).\u003c\/p\u003e\n\u003cp\u003eThis device mounts on a HiC Termination Board.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca title=\"SMART Universal Barrier HiC2441 Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/315318_eng.pdf?v=1718807633\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/t48403_eng_1.pdf?v=1603565705\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003c!----\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"HiC2441","offer_id":41005612302533,"sku":"315318","price":519.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/93E070A0-275D-441B-8972-E895898F91B8.png?v=1718807848"},{"product_id":"hic2851-switch-amplifier","title":"HiC2851, Switch Amplifier","description":"\u003ch4\u003eSwitch Amplifier, HiC2851\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (bus powered)\u003c\/li\u003e\n\u003cli\u003eInput for approved dry contacts or SN\/S1N sensors\u003c\/li\u003e\n\u003cli\u003eActive voltage output\u003c\/li\u003e\n\u003cli\u003ePassive transistor output (resistive acc. to EN 60947-5-6)\u003c\/li\u003e\n\u003cli\u003eLine fault transparency (LFT)\u003c\/li\u003e\n\u003cli\u003eUp to SIL 3 acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device transfers digital signals (SN\/S1N proximity sensors or approved dry contacts) from a hazardous area to a safe area.\u003c\/p\u003e\n\u003cp\u003eThe input controls one 24 V DC active voltage output and one passive transistor output with a resistive output characteristic (acc. to EN 60947-5-6).\u003c\/p\u003e\n\u003cp\u003eThe passive transistor output has three defined states: 1-Signal = 1.8 kΩ, 0-Signal = 14 kΩ and fault \u0026gt; 100 kΩ.\u003c\/p\u003e\n\u003cp\u003eLead breakage (LB) and short circuit (SC) conditions of the control circuit are continuously monitored.\u003c\/p\u003e\n\u003cp\u003eUnlike a SN\/S1N series safety sensor, an approved dry contact requires a 10 kΩ resistor to be placed across the contact in addition to a 1.5 kΩ resistor in series.\u003c\/p\u003e\n\u003cp\u003eThis device mounts on a HiC termination board.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"HiC2851","offer_id":36629477490841,"sku":"257611","price":530.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/67979281-F75F-4124-BF3A-987B5A9E7896.png?v=1641484305"},{"product_id":"hidtb08-sdc-49c-sc-ra-termination-board","title":"HIDTB08-SDC-49C-SC-RA, Termination Board","description":"\u003ch4\u003eTermination Board, HIDTB08-SDC-49C-SC-RA\u003c\/h4\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003eFor 8 modules\u003c\/li\u003e\n\u003cli\u003e24 V DC supply\u003c\/li\u003e\n\u003cli\u003eSupported signal types: DI\/DO\/AI\/TI\/AO\u003c\/li\u003e\n\u003cli\u003eHazardous area: screw terminals, blue\u003c\/li\u003e\n\u003cli\u003eNon-hazardous area: Sub-D connector (male), 37-pin\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe termination board has 8 plugin slots for isolators. Any isolator can be inserted into any slot, enabling a mixture of I\/O types on one termination board.\u003c\/p\u003e\n\u003cp\u003eThe termination board features fixed screw terminals for the field side connection and a 37-pin Sub- D connector for the control side connection along with a HART cordset for interconnection to a separate HART Communication Board.\u003c\/p\u003e\n\u003cp\u003eInformation about missing supply voltage of the isolators is available for the system as volt-free contact at the redundant power supply terminals. Wiring errors from field side will be reported via the same relay contact, if this function supported by the the isolators. The termination board is supplied with a robust plastic housing as standard. This design permits the fast and reliable installation on 35 mm DIN mounting rail acc. to EN 60715 in the cabinet.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"HIDTB08-SDC-49C-SC-RA","offer_id":36629496955033,"sku":"302570","price":524.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/5CC44620-B8ED-487F-8C87-FF7D92733973.png?v=1641503894"},{"product_id":"kfd2-stc5-1-2o-smart-transmitter-power-supply","title":"KFD2-STC5-1.2O, SMART Transmitter Power Supply","description":"\u003ch4\u003eSMART Transmitter Power Supply KFD2-STC5-1.2O\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1-channel signal conditioner\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eInput 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources\u003c\/li\u003e\n\u003cli\u003eSignal splitter (1 input and 2 outputs)\u003c\/li\u003e\n\u003cli\u003eDual output 0\/4 mA ... 20 mA, current sink\/current source\u003c\/li\u003e\n\u003cli\u003eTerminals with test points\u003c\/li\u003e\n\u003cli\u003eSIL 2 (SC 3) acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis signal conditioner provides the galvanic isolation between field circuits and control circuits. The device supplies 2-wire and 3-wire SMART transmitters, and can also be used with 2-wire SMART current sources. It transfers the analog input signal to the control side as two isolated output signals. Digital signals may be superimposed on the input signal on the field side or on the control side and are transferred bi-directionally. The device provides a sink mode or a source mode output on the control side terminals. The device has an internal resistor. Use this resistor if the HART communication resistance in the control circuit is too low. Test sockets for the connection of HART communicators are integrated into the terminals of the device.\u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFD2-STC5-1.2O","offer_id":41005645201605,"sku":"239215","price":460.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/9ED318DA-785C-4E2D-A3C4-96605E03607C.png?v=1766528487"},{"product_id":"kfu8-crg2-1-d","title":"Transmitter Power Supply KFU8-CRG2-1.D","description":"\u003ch1\u003eKFU8-CRG2-1.D, Transmitter Power Supply\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e1-channel signal conditioner \u003c\/li\u003e\n\u003cli\u003eUniversal usage at different power supplies\u003c\/li\u003e\n\u003cli\u003eInput 2-wire and 3-wire transmitters and 2-wire current sources\u003c\/li\u003e\n\u003cli\u003eOutput 0\/4 mA ... 20 mA\u003c\/li\u003e\n\u003cli\u003e2 relay contact outputs\u003c\/li\u003e\n\u003cli\u003eAdjustable energized\/de-energized delay\u003c\/li\u003e\n\u003cli\u003eProgrammable high\/low alarm\u003c\/li\u003e\n\u003cli\u003eLinearization function (max 20 points)\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD) \u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 acc. to IEC\/EN 61508 \/ IEC\/EN 61511\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis signal conditioner provides galvanic isolation between field circuits and control circuits.\u003c\/p\u003e\n\u003cp\u003eThe device supplies 2-wire and 3-wire transmitters, and can also be used with current sources.\u003c\/p\u003e\n\u003cp\u003eTwo relays and an active 0\/4 mA to 20 mA current source are available as outputs. The relay contacts and the current output can be integrated in safety-relevant circuits. The current output is easily scaled.\u003c\/p\u003e\n\u003cp\u003eOn the display the measured value can be indicated in various physical units.\u003c\/p\u003e\n\u003cp\u003eThe device is easily configured by the use of keypad or with the PACTware configuration software.\u003c\/p\u003e\n\u003cp\u003eThe input has a line fault detection.\u003c\/p\u003e\n\u003cp\u003eA fault is signalized by LEDs.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFU8-CRG2-1.D","offer_id":41005648511173,"sku":"255623","price":640.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/0B15A300-7E55-482B-98DE-D73E3B94203D.png?v=1766520478"},{"product_id":"kcd2-sr-ex1-lb","title":"Switch Amplifier KCD2-SR-EX1.LB","description":"\u003ch1 class=\"alternative\"\u003eSwitch Amplifier KCD2-SR-EX1.LB\u003c\/h1\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003e1-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eDry contact or NAMUR inputs\u003c\/li\u003e\n\u003cli\u003eUsable as signal splitter (1 input and 2 outputs)\u003c\/li\u003e\n\u003cli\u003eRelay contact output\u003c\/li\u003e\n\u003cli\u003eFault relay contact output\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eHousing width 12.5 mm\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 acc. to IEC\/EN 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003c\/p\u003e\n\u003cp\u003eThe device transfers digital signals from NAMUR sensors or dry contacts from the hazardous area to the non-hazardous area.\u003c\/p\u003e\n\u003cp\u003eThe proximity sensor or the mechanical contact controls the control side load for a relay contact output. The device output changes the state when the input signal changes the state.\u003c\/p\u003e\n\u003cp\u003eVia switches the mode of operation can be reversed and the line fault detection can be switched off.\u003c\/p\u003e\n\u003cp\u003eDuring a fault condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE 44.\u003c\/p\u003e\n\u003cp\u003eIf the device is operated via Power Rail, additionally a collective error message is available.\u003c\/p\u003e\n\u003cp\u003eDue to its compact housing design and low heat dissipation, this device is useful for detecting positions, end stops, and switching states in space-critical applications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%;\" class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 524px;\" colspan=\"2\" class=\"tg-yg9r\"\u003eProduct Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-riw3\"\u003e\u003cstrong\u003e24 V DC supply (Power Rail)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eGeneral specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eSignal type\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eDigital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eFunctional safety related parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eSafety Integrity Level (SIL)\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eSIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eSupply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jnh8\"\u003ePower Rail or terminals 9+, 10-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eRated voltage\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jnh8\"\u003e19 ... 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eRipple\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003e≤ 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eRated current\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jnh8\"\u003e≤ 37 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003ePower dissipation\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003e≤ 750 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003e≤ 750 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eInput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eConnection side\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003efield side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eterminals 1+, 2-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eRated values\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eacc. to EN 60947-5-6 (NAMUR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eOpen circuit voltage\/short-circuit current\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eapprox. 8 V DC \/ approx. 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eSwitching point\/switching hysteresis\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003e1.2 ... 2.1 mA \/ approx. 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eLine fault detection\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jnh8\"\u003ebreakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003ePulse\/Pause ratio\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003emin. 20 ms \/ min. 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eOutput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eConnection side\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003econtrol side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eoutput I: terminals 5, 6 ; output II: terminals 7, 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eOutput I\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003esignal ; relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eOutput II\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003esignal or error message ; relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eContact loading\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jnh8\"\u003e250 V AC\/2 A\/cos φ \u0026gt; 0.75; 126.5 V AC\/4 A\/cos φ \u0026gt; 0.75; 30 V DC\/2 A resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eMinimum switch current\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003e2 mA \/ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eEnergized\/De-energized delay\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003e≤ 20 ms \/ ≤ 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eMechanical life\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003e10\u003csup\u003e7\u003c\/sup\u003e switching cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eTransfer characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003e≤ 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eGalvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eInput\/Output\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003ereinforced insulation acc. to IEC\/EN 61010-1, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eInput\/power supply\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003ereinforced insulation acc. to \u003cspan data-mce-fragment=\"1\"\u003eIEC\/EN 61010-1\u003c\/span\u003e, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eOutput\/power supply\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jnh8\"\u003ereinforced insulation acc. to IEC\/EN 61010-1, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eOutput\/Output\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jnh8\"\u003ereinforced insulation acc. toIEC\/EN 61010-1, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eIndicators\/settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eDisplay elements\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jnh8\"\u003eLEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eControl elements\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jnh8\"\u003eDIP-switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003evia DIP switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eLabeling\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003espace for labeling at the front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eDirective conformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-riw3\"\u003e\u003cstrong\u003eElectromagnetic compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-sa29\"\u003eDirective 2014\/30\/EU\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jnh8\"\u003eEN 61326-1:2013 (industrial locations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-riw3\"\u003e\u003cstrong\u003eLow voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-sa29\"\u003eDirective 2014\/35\/EU\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eEN 61010-1:2010+A1:2019+A1:2019\/AC:2019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eConformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eNE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eIEC 60529:1989+A1:1999+A2:2013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eFunctional safety\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eIEC\/EN 61508:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eInput\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eEN 60947-5-6:2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eAmbient conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003e-40 ... 70 °C (-40 ... 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-wqna\"\u003eMechanical specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003escrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eMass\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-4pow\"\u003eapprox. 100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-riw3\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-riw3\"\u003e12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-jmxk\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003eon 35 mm DIN mounting rail acc. to EN 60715:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-v47f\"\u003eData for application in connection with hazardous areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-jmxk\"\u003eEU-type examination certificate\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003eBASEEFA 06 ATEX 0092 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003eMarking\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003e\n\u003cimg data-mce-fragment=\"1\" alt=\"Explosion proof hexagon\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/Ex.jpg?v=1650314955\"\u003e II 3(1)G Ex ec nC [ia Ga] IIC T4 Gc , \u003cimg data-mce-fragment=\"1\" alt=\"Explosion Proof Hexagon\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/Ex.jpg?v=1650314955\"\u003e \u003cspan data-mce-fragment=\"1\"\u003eII (1)D [Ex ia Da] IIIC, \u003cimg data-mce-fragment=\"1\" alt=\"Explosion Proof Hexagon\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/Ex.jpg?v=1650314955\"\u003e I (M1) [Ex ia Ma] I\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-dq9x\"\u003eInput\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-w9xl\"\u003e\u003cspan\u003eEx ia\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-dq9x\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003e10.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003e34 mW (linear characteristic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-jmxk\"\u003eSupply \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003eMaximum safe voltage\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003e\n\u003cspan\u003e253 V AC (Attention! U\u003c\/span\u003e\u003csub\u003em\u003c\/sub\u003e\u003cspan\u003e is no rated voltage.)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-jmxk\"\u003eOutput \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003eContact loading\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003e\u003cspan\u003eZone 2 : 50 V AC\/2 A\/cos φ \u0026gt; 0.75; 30 V DC\/2 A resistive load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003eMaximum safe voltage\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003e253 V AC (Attention! The rated voltage can be lower.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-jmxk\"\u003eFault indication output \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003eMaximum safe voltage\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003e40 V DC (Attention! Um is no rated voltage.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-jmxk\"\u003eGalvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003eInput\/Output\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003esafe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-dq9x\"\u003eInput\/power supply\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003esafe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-jmxk\"\u003eDirective conformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003eDirective 2014\/34\/EU\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003eEN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-v47f\"\u003eInternational approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-jmxk\"\u003eUL approval\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003eE106378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003eControl drawing\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003e116-0420 (cULus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-jmxk\"\u003eIECEx approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003eIECEx certificate\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003eIECEx BAS 06.0025 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-9h3u\"\u003eIECEx marking\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-jmxk\"\u003eEx ec nC [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 524px;\" colspan=\"2\" class=\"tg-v47f\"\u003eGeneral information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 100.386px;\" class=\"tg-0lax\"\u003eSupplementary information\u003c\/td\u003e\n\u003ctd style=\"width: 412.614px;\" class=\"tg-0lax\"\u003eObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see - www.control-automation.com\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KCD2-SR-EX1.LB","offer_id":41005641728197,"sku":"70112151","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/A6BC04A7-7EA2-4287-892E-603C63CB28BA.png?v=1650314241"},{"product_id":"kcd2-sr-ex2","title":"Switch Amplifier KCD2-SR-Ex2","description":"\u003ch3 class=\"h2\" itemprop=\"name\"\u003eSwitch Amplifier KCD2-SR-EX2\u003c\/h3\u003e\n\u003cdiv\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e2-channel isolated barrier\u003c\/li\u003e\n\u003cli\u003e24 V DC supply (Power Rail)\u003c\/li\u003e\n\u003cli\u003eDry contact or NAMUR inputs\u003c\/li\u003e\n\u003cli\u003eRelay contact output\u003c\/li\u003e\n\u003cli\u003eLine fault detection (LFD)\u003c\/li\u003e\n\u003cli\u003eHousing width 12.5 mm\u003c\/li\u003e\n\u003cli\u003eUp to SIL 2 acc. to IEC 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul style=\"color: #3366cc;\"\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThis isolated barrier is used for intrinsic safety applications.\u003cbr\u003eThe device transfers digital signals from NAMUR sensors or dry contacts from the hazardous area to the non-hazardous area.\u003cbr\u003eThe proximity sensor or the mechanical contact controls the control side load for a relay contact output. The device output changes the state when\u003cbr\u003ethe input signal changes the state.\u003cbr\u003eVia switches the mode of operation can be reversed and the line fault detection can be switched off.\u003cbr\u003eDuring a fault condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE 44.\u003cbr\u003eIf the device is operated via Power Rail, additionally a collective error message is available.\u003cbr\u003eDue to its compact housing design and low heat dissipation, this device is useful for detecting positions, end stops, and switching states in spacecritical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border:none;border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:0px;color:#444;\n  font-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:0px;color:#fff;\n  font-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-yg9r{border-color:inherit;font-size:18px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-8hyk{background-color:#409cff;border-color:#409cff;color:#ffffff;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:top}\n.tg .tg-jnh8{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:top}\n.tg .tg-c3ow{border-color:inherit;text-align:center;vertical-align:top}\n.tg .tg-v47f{background-color:#409cff;color:#ffffff;font-size:18px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-h1e6{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:center;vertical-align:top}\n.tg .tg-0pky{border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-wqna{background-color:#409cff;border-color:inherit;color:#ffffff;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:top}\n.tg .tg-4pjd{background-color:#409cff;border-color:#3166ff;color:#efefef;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:top}\n.tg .tg-zd5i{border-color:inherit;font-size:14px;text-align:left;vertical-align:top}\n.tg .tg-h6w4{border-color:inherit;font-size:15px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-05q9{background-color:#ebf5ff;border-color:inherit;font-size:15px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-sa29{background-color:#ebf5ff;border-color:inherit;text-align:center;vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" class=\"tg-yg9r\"\u003eGeneral Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eSignal Type\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eDigital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-wqna\"\u003eFunctional safety-related parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eSafety Integrity Level (SIL)\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eSIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-4pjd\"\u003eSupply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003ePower Rail or terminals 9+, 10-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eRated voltage\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e19 ... 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e≤ 600 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eRipple\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e≤ 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eRated current\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e≤ 30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003ePower dissipation\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e≤ 600 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-8hyk\"\u003eInput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eConnection side\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003efield side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eterminals 1+, 2-; 3+, 4-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eRated values\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eacc. to EN 60947-5-6 (NAMUR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eOpen circuit voltage\/short-circuit current\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eapprox. 10 V DC \/ approx. 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eSwitching point\/switching hysteresis\u003c\/td\u003e\n\u003ctd class=\"tg-zd5i\"\u003e1.2 ... 2.1 mA \/ approx. 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eLine fault detection\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003ebreakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003ePulse\/Pause ratio\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003emin. 20 ms \/ min. 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-8hyk\"\u003eOutput\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eConnection side\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003econtrol side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eterminals 5, 6; 7, 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eOutput I\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003esignal ; relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eOutput II\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003esignal ; relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eContact loading\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e253 V AC\/2 A\/cos φ \u0026gt; 0.7; 126.5 V AC\/4 A\/cos φ \u0026gt; 0.7; 30 V DC\/2 A resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eMinimum switch current\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e2 mA \/ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eEnergized\/De-energized delay\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e≤ 20 ms \/ ≤ 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eMechanical life\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e10\u003csup\u003e7\u003c\/sup\u003e switching cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-wqna\"\u003eTransfer characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e≤ 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-wqna\"\u003eGalvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eInput\/Output\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003ereinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eInput\/power supply\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003ereinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eOutput\/power supply\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003ereinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eInput\/input\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eBasic insulation according to EN 50178, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eOutput\/Output\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003ereinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-wqna\"\u003eIndicators\/settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eDisplay elements\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eLEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eControl elements\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eDIP-switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003evia DIP switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eLabeling\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003espace for labeling at the front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-wqna\"\u003eDirective conformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eDirective 2014\/30\/EU\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eEN 61326-1:2013 (industrial locations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eLow voltage\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eDirective 2014\/30\/EU\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eEN 61326-1:2013 (industrial locations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-wqna\"\u003eConformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eNE 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eIEC 60529:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-v47f\"\u003eAmbient conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e-20 ... 60 °C (-4 ... 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-wqna\"\u003eMechanical specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003espring terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eMass\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eapprox. 100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eMounting\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eon 35 mm DIN mounting rail acc. to EN 60715:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-wqna\"\u003eData for application in connection with hazardous areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h6w4\"\u003eEU-type examination certificate\u003c\/td\u003e\n\u003ctd class=\"tg-05q9\"\u003eBASEEFA 06 ATEX 0092\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eMarking\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eEx-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eInput\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e10.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eCurrent\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e17.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e45 mW (linear characteristic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-h6w4\"\u003eSupply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eMaximum safe voltage\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e253 V AC (Attention! Um is no rated voltage.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-h6w4\"\u003eOutput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eContact loading\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e253 V AC\/2 A\/cos φ \u0026gt; 0.7; 126.5 V AC\/4 A\/cos φ \u0026gt; 0.7; 30 V DC\/2 A resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eMaximum safe voltage\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e253 V AC (Attention! The rated voltage can be lower.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eCertificate\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003ePF 06 CERT 0972 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eMarking\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eEx-Hexagon II 3G Ex nA nC IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h6w4\"\u003eOutput I, II\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eContact loading\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e50 V AC\/2 A\/cos φ \u0026gt; 0.7; 30 V DC\/2 A resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h6w4\"\u003eGalvanic isolation\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eInput\/Output\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003esafe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eInput\/power supply\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003esafe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h6w4\"\u003eDirective conformity\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eDirective 2014\/34\/EU\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-wqna\"\u003eInternational approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-h6w4\"\u003eFM approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eControl drawing\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e116-0419 (cFMus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"tg-h6w4\"\u003eUL approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eControl drawing\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e116-0420 (cULus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h6w4\"\u003eIECEx approval\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003eIECEx BAS 06.0025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-c3ow\"\u003eApproved for\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\"\u003eGeneral information\u003c\/td\u003e\n\u003ctd class=\"tg-wqna\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0pky\"\u003eSupplementary Information\u003c\/td\u003e\n\u003ctd class=\"tg-0pky\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see - www.control-automation.com\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KCD2-SR-EX2","offer_id":41005641826501,"sku":"70112153","price":290.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/products\/C3BA6C15-88FD-447C-9CD1-45DDE502F4EA.png?v=1640906282"},{"product_id":"kfa5-sr2-ex1-w","title":"Switch Amplifier, KFA5-SR2-EX1.W","description":"\u003ch3 class=\"alternative\" data-mce-fragment=\"1\"\u003e\n\u003cspan\u003eSwitch Amplifier, Timer Relay \u003c\/span\u003e\u003cspan\u003eKFA5-SR2-EX1.W\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul style=\"color: blue;\" id=\"productfeatures\"\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e1-channel isolated barrier\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e115 V AC supply\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eDry contact or NAMUR inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eRelay contact output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eLine fault detection (LFD)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eReversible mode of operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eUp to SIL 2 acc. to IEC 61508\/IEC 61511\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eThis isolated barrier is used for intrinsic safety applications. It transfers digital signals (NAMUR sensors\/mechanical contacts) from a hazardous area to a safe area. The proximity sensor or switch controls a form C changeover relay contact for the safe area load. The barrier output changes state when the input signal changes state. The normal output state can be reversed using switch S1. Switch S3 is used to enable or disable line fault detection of the field circuit. During an error condition, relays revert to their de-energized state and LEDs indicate the fault according to NAMUR NE44.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\n.tg  {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\n  font-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\n  font-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-8wjn{background-color:#409cff;border-color:inherit;color:#efefef;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:middle}\n.tg .tg-kivi{background-color:#ebf5ff;border-color:inherit;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-get6{background-color:#409cff;border-color:inherit;color:#FFF;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:middle}\n.tg .tg-jnh8{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:top}\n.tg .tg-v47f{background-color:#409cff;color:#ffffff;font-size:18px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-h1e6{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:center;vertical-align:top}\n.tg .tg-lvgc{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:middle}\n.tg .tg-iq83{background-color:#409cff;border-color:inherit;color:#efefef;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:top}\n.tg .tg-sa29{background-color:#ebf5ff;border-color:inherit;text-align:center;vertical-align:top}\n.tg .tg-riw3{background-color:#ebf5ff;border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-wqna{background-color:#409cff;border-color:inherit;color:#ffffff;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n--\u003e\u003c\/style\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-color:#9ABAD9;border-spacing:0;}\n.tg td{background-color:#EBF5FF;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#444;\n  font-family:Arial, sans-serif;font-size:14px;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{background-color:#409cff;border-color:#9ABAD9;border-style:solid;border-width:1px;color:#fff;\n  font-family:Arial, sans-serif;font-size:14px;font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-8wjn{background-color:#409cff;border-color:inherit;color:#efefef;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:middle}\n.tg .tg-kivi{background-color:#ebf5ff;border-color:inherit;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-get6{background-color:#409cff;border-color:inherit;color:#FFF;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:middle}\n.tg .tg-jnh8{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:top}\n.tg .tg-v47f{background-color:#409cff;color:#ffffff;font-size:18px;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-h1e6{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:center;vertical-align:top}\n.tg .tg-lvgc{background-color:#ebf5ff;border-color:inherit;color:#425563;text-align:left;vertical-align:middle}\n.tg .tg-iq83{background-color:#409cff;border-color:inherit;color:#efefef;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:top}\n.tg .tg-sa29{background-color:#ebf5ff;border-color:inherit;text-align:center;vertical-align:top}\n.tg .tg-riw3{background-color:#ebf5ff;border-color:inherit;text-align:left;vertical-align:top}\n.tg .tg-wqna{background-color:#409cff;border-color:inherit;color:#ffffff;font-size:18px;font-weight:bold;text-align:left;\n  vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-8wjn\" colspan=\"2\"\u003eGeneral specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eSignal type\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003eDigital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-get6\" colspan=\"2\"\u003e\u003cspan style=\"font-weight: normal; color: #fff;\"\u003eFunctional safety related parameters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eSafety Integrity Level (SIL)\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003eSIL 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-get6\" colspan=\"2\"\u003e\u003cspan style=\"color: #fff;\"\u003eSupply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003eterminals 14, 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eRated voltage\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003e103.5 ... 126 V AC , 45 ... 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-8wjn\" colspan=\"2\"\u003eInput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eConnection side\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003efield side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003eterminals 1+, 2+, 3-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eRated values\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003eacc. to EN 60947-5-6 (NAMUR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eOpen circuit voltage\/short-circuit current\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003eapprox. 8 V DC \/ approx. 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eSwitching point\/switching hysteresis\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003e1.2 ... 2.1 mA \/ approx. 0.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eLine fault detection\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003ebreakage I ≤ 0.1 mA , short-circuit I \u0026gt; 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003ePulse\/Pause ratio\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003emin. 20 ms \/ min. 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-get6\" colspan=\"2\"\u003e\u003cspan style=\"color: #fff;\"\u003eOutput\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eConnection side\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003econtrol side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003eterminals 7, 8, 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eOutput\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003esignal, relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eContact loading\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003e253 V AC\/2 A\/cos φ \u0026gt; 0.7; 126.5 V AC\/4 A\/cos φ \u0026gt; 0.7; 40 V DC\/2 A resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eEnergized\/De-energized delay\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003eapprox. 20 ms \/ approx. 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eMechanical life\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003e107 switching cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-get6\" colspan=\"2\"\u003e\u003cspan style=\"color: #fff;\"\u003eTransfer characteristics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003e\u0026lt; 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-get6\" colspan=\"2\"\u003e\u003cspan style=\"color: #fff;\"\u003eGalvanic isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eInput\/Output\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003ereinforced insulation according to IEC\/EN 61010-1, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eInput\/power supply\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003ereinforced insulation according to IEC\/EN 61010-1, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eOutput\/power supply\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003ereinforced insulation according to IEC\/EN 61010-1, rated insulation voltage 300 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-get6\" colspan=\"2\"\u003e\u003cspan style=\"color: #fff;\"\u003eIndicators\/settings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eDisplay elements\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003eLEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eControl elements\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003eDIP-switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003evia DIP switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lvgc\"\u003eLabeling\u003c\/td\u003e\n\u003ctd class=\"tg-lvgc\"\u003espace for labeling at the front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-iq83\" colspan=\"2\"\u003eDirective conformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-kivi\" colspan=\"2\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eDirective 2014\/30\/EU\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eEN 61326-1:2013 (industrial locations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-kivi\" colspan=\"2\"\u003eLow voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eDirective 2014\/35\/EU\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eEN 61010-1:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-iq83\" colspan=\"2\"\u003eConformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eNE 21:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eIEC 60529:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eInput\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eEN 60947-5-6:2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-iq83\" colspan=\"2\"\u003eAmbient conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e-20 ... 60 °C (-4 ... 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-iq83\" colspan=\"2\"\u003eMechanical specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003escrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eMass\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eapprox. 150 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eMounting\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eon 35 mm DIN mounting rail acc. to EN 60715:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-iq83\" colspan=\"2\"\u003eData for application in connection with hazardous areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-riw3\"\u003eEU-Type Examination Certificate\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003ePTB 00 ATEX 2081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eMarking\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e\n\u003cimg src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" width=\"17\" height=\"16\"\u003e# II (1)G [Ex ia Ga] IIC\u003cbr\u003e\u003cimg src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" width=\"17\" height=\"16\"\u003e# II (1)D [Ex ia Da] IIIC\u003cbr\u003e\u003cimg src=\"https:\/\/www.pepperl-fuchs.com\/web_img\/a100038a.jpg\" alt=\"Ex-Hexagon\" width=\"17\" height=\"16\"\u003e# I (M1) [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eInput\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eEx ia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e10.6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eCurrent\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e19.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e51 mW (linear characteristic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-kivi\" colspan=\"2\"\u003eSupply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eMaximum safe voltage\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e126.5 V AC (Attention! Um is no rated voltage.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-kivi\" colspan=\"2\"\u003eOutput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eContact loading\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e253 V AC\/2 A\/cos φ \u0026gt; 0.7; 126.5 V AC\/4 A\/cos φ \u0026gt; 0.7; 40 V DC\/2 A resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eMaximum safe voltage\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e253 V AC (Attention! The rated voltage can be lower.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-kivi\" colspan=\"2\"\u003eGalvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eInput\/Output\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003esafe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eInput\/power supply\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003esafe electrical isolation acc. to IEC\/EN 60079-11, voltage peak value 375 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-kivi\" colspan=\"2\"\u003eDirective conformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eDirective 2014\/34\/EU\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003eEN 60079-0:2012+A11:2013 , EN 60079-11:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wqna\" colspan=\"2\"\u003eInternational approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-kivi\" colspan=\"2\"\u003eFM approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-h1e6\"\u003eControl drawing\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e116-0035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-kivi\" colspan=\"2\"\u003eUL approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eControl drawing\u003c\/td\u003e\n\u003ctd class=\"tg-jnh8\"\u003e116-0145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-kivi\" colspan=\"2\"\u003eCSA approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eControl drawing\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e116-0047\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eIECEx approval\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003eIECEx PTB 11.0031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-sa29\"\u003eApproved for\u003c\/td\u003e\n\u003ctd class=\"tg-riw3\"\u003e[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-v47f\" colspan=\"2\"\u003eGeneral information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-0lax\"\u003eSupplementary information\u003c\/td\u003e\n\u003ctd class=\"tg-0lax\"\u003eObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see - www.control-automation.com\/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Pepperl+Fuchs Process Automation","offers":[{"title":"KFA5-SR2-EX1.W","offer_id":41005646577861,"sku":"KFA5-SR2-EX1.W","price":293.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0494\/9914\/4345\/files\/5BC7F877-0F37-4E34-8EA4-CCBB32D4E98F.png?v=1733505319"}],"url":"https:\/\/control-automation.com\/collections\/pepperl-fuchs-in-stock-items\/purge-7500-series.oembed","provider":"Control Automation","version":"1.0","type":"link"}