Switch Amplifier KCD2-SR-EX2

  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Housing width 12.5 mm
  • Up to SIL 2 acc. to IEC 61508

    This isolated barrier is used for intrinsic safety applications.
    The device transfers digital signals from NAMUR sensors or dry contacts from the hazardous area to the non-hazardous area.
    The proximity sensor or the mechanical contact controls the control side load for a relay contact output. The device output changes the state when
    the input signal changes the state.
    Via switches the mode of operation can be reversed and the line fault detection can be switched off.
    During a fault condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE 44.
    If the device is operated via Power Rail, additionally a collective error message is available.
    Due to its compact housing design and low heat dissipation, this device is useful for detecting positions, end stops, and switching states in spacecritical applications.


    General Specification
    Signal Type Digital Input
    Functional safety-related parameters
    Safety Integrity Level (SIL) SIL 2
    Supply
    Connection Power Rail or terminals 9+, 10-
    Rated voltage 19 ... 30 V DC
    Power consumption ≤ 600 mW
    Ripple ≤ 10 %
    Rated current ≤ 30 mA
    Power dissipation ≤ 600 mW
    Input
    Connection side field side
    Connection terminals 1+, 2-; 3+, 4-
    Rated values acc. to EN 60947-5-6 (NAMUR)
    Open circuit voltage/short-circuit current approx. 10 V DC / approx. 8 mA
    Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
    Line fault detection breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
    Pulse/Pause ratio min. 20 ms / min. 20 ms
    Output
    Connection side control side
    Connection terminals 5, 6; 7, 8
    Output I signal ; relay
    Output II signal ; relay
    Contact loading 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 30 V DC/2 A resistive load
    Minimum switch current 2 mA / 24 V DC
    Energized/De-energized delay ≤ 20 ms / ≤ 20 ms
    Mechanical life 107 switching cycles
    Transfer characteristics
    Switching frequency ≤ 10 Hz
    Galvanic isolation
    Input/Output reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
    Input/power supply reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
    Output/power supply reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
    Input/input Basic insulation according to EN 50178, rated insulation voltage 300 Veff
    Output/Output reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
    Indicators/settings
    Display elements LEDs
    Control elements DIP-switch
    Configuration via DIP switches
    Labeling space for labeling at the front
    Directive conformity
    Electromagnetic compatibility
    Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
    Low voltage
    Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
    Conformity
    Electromagnetic compatibility NE 21
    Degree of protection IEC 60529:2001
    Ambient conditions
    Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
    Mechanical specifications
    Degree of protection IP20
    Connection spring terminals
    Mass approx. 100 g
    Dimensions 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
    Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
    Data for application in connection with hazardous areas
    EU-type examination certificate BASEEFA 06 ATEX 0092
    Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I
    Input [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
    Voltage 10.5 V
    Current 17.1 mA
    Power 45 mW (linear characteristic)
    Supply
    Maximum safe voltage 253 V AC (Attention! Um is no rated voltage.)
    Output
    Contact loading 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 30 V DC/2 A resistive load
    Maximum safe voltage 253 V AC (Attention! The rated voltage can be lower.)
    Certificate PF 06 CERT 0972 X
    Marking Ex-Hexagon II 3G Ex nA nC IIC T4 Gc
    Output I, II
    Contact loading 50 V AC/2 A/cos φ > 0.7; 30 V DC/2 A resistive load
    Galvanic isolation
    Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
    Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
    Directive conformity
    Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
    International approvals
    FM approval
    Control drawing 116-0419 (cFMus)
    UL approval
    Control drawing 116-0420 (cULus)
    IECEx approval IECEx BAS 06.0025
    Approved for [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
    General information
    Supplementary Information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see - www.control-automation.com